OVERVIEW
The 2500 Series® Slice I/O System is designed for use in a broad range of applications.
It is compatible with the 2500 Series® Programmable Automation Control System and
offers users the ability to place I/O points in multiple remote locations without the need
for I/O bases and RBCs.

Slice I/O modules communicate to 2500 Series® Processors using CAMP protocol and
read/write directly to the PLC memory or I/O image table.This allowstransparent integration
into the 2500 Series® system without the requirement for any complicated configuration
step. Ethernet connection to the CPU can be accomplished using the on-board port on
2500-Cxxx Processors, using a 2572 / 2572-A/B Ethernet module, or using the 2500P-ECC1
Ethernet Communications Coprocessor. Note that when using 2572 or 2572-A/B modules,
Slice I/O can be connected even to legacy Siemens® and Texas Instruments PLCs.
Several models of Slice I/O are available with different mixes of I/O and with additional
communications options including RS232/485 and 900MHz radio. Slice I/O modules feature
Universal Analog Inputs which allow connection of 0-5V, 0-20mA, thermocouple, and RTD
sensors.
All Slice I/O modules can also be configured to communicate over Ethernet using Modbus-TCP
to allow connection to DCS and other automation controllers.
Powerful & Cost-Effective Ethernet I/O
The 2500S family of Slice I/O modules expands the capability of 2500 Series® Systems
to include small modules of I/O connected over Ethernet. It offersmodularity down to a
few I/O points without the need for an I/O base and RBC.
The CTI 2500 Series® Slice Ethernet I/O System offers:
• Connection to CTI and legacy Siemens®/TI CPUs over Ethernet using CAMP
• Connection to DCS or other automation controllers using Modbus-TCP
• Several models with differing I/O capabilities to customize the solution to your needs
• Serial RS232/485 and 900MHz radio options for additional communications flexibility (900MHz
wireless subject to import limitation, depending on country)
• Extensive intelligent features for processing attached I/O signals:
Totalization, filtering, forcing, inversion, runtime, and counting on digital inputs
Frequency out (with PWM) and synchronization on digital outputs
Filtering, averaging, scaling and totalization on analog inputs
Data logging and trending
• All module configuration done using a simple web browser interface
• Wide –40°C to +70°C operating temperature range
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com