Features
• A protection, control, and monitoring IED with extensive functional library and configuration
possibilities and expandable hardware design to meet specific user requirements
• For overhead lines and cables
• For transformer feeders
• For single and/or three phase tripping
• High impedance differential protection for tee-feeders
• Phase-segregated line differential protection with up to six stabilized inputs for up to five line terminals with:
- Charging current compensation
- Separate inputs for each CT in double breaker, ring and one and a half breaker
installations for improved through fault stability
- Suitable for multiplexed, route switched, as well as dedicated fibre, communication networks using C37.94 protocol
- Power transformers can be included in the protected zone
- Transfer of up to eight binary signals
- Time synchronization with the echo-method or built-in GPS
• Full scheme phase-to-phase and phase-to-earth distance protection with up to three zones:
- All types of scheme communication
- Load encroachment feature
• Synchrocheck and dead-line check function for single- or multi-breaker arrangements:
- Selectable energizing direction
- Two functions with built-in voltage selection
- For automatic or manual synchrocheck and with different settings
• Auto-reclosing function for single- two-, and/or three-phase reclosing:
- Two functions with priority circuits for multi-breaker arrangements
- Co-operation with synchrocheck function
- Can be switched On-Off from remote through communication or with local switches through binary inputs
• Selectable additional software functions such as distance protection, control and monitoring
• Built-in data communication modules for station bus IEC 61850-8-1
• Data communication modules for station bus IEC 60870-5-103. LON and SPA
• Integrated disturbance and event recorder for up to 40 analog and 96 binary signals
• Time synchronization over IEC 61850-8-1. LON,SPA, binary input or with optional GPS module
• Analog measurements accuracy up to below 0.5% for power and 0.25% for current and voltage and with site calibration to optimize total accuracy
• Versatile local human-machine interface
• Extensive self-supervision with internal event recorder
• Six independent groups of complete setting parameters with password protection
• Powerful software PC tool for setting, disturbance evaluation and configuration
• Remote end data communication modules for C37.94 and G.703