Functions
• Differential protection
- Transformer differential protection, two winding (PDIF, 87T)
- Transformer differential protection, three winding (PDIF, 87T)
- Restricted earth fault protection (PDIF, 87N)
- High impedance differential protection (PDIF, 87X)
• Distance protection
- Distance protection zones (PDIS, 21)
- Phase selection with load encroachment (PDIS, 21)
- Power swing detection (RPSB, 78)
- Automatic switch onto fault logic (PSOF)
• Current protection
- Instantaneous phase overcurrent protection (PIOC, 50)
- Four step phase overcurrent protection (POCM, 51/67)
- Instantaneous residual overcurrent protection (PIOC, 50N)
- Four step residual overcurrent protection (PEFM, 51N/67N)
- Thermal overload protection, two time constants (PTTR, 49)
- Breaker failure protection (RBRF, 50BF)
- Pole discordance protection (RPLD, 52PD)
• Voltage protection
- Two step undervoltage protection (PUVM, 27)
- Two step overvoltage protection (POVM, 59)
- Two step residual overvoltage protection(POVM , 59N)
- Overexcitation protection (PVPH, 24)
• Frequency protection
- Underfrequency protection (PTUF, 81)
- Overfrequency protection (PTOF, 81)
- Rate-of-change frequency protection (PFRC, 81)
• Multipurpose protection
- General current and voltage protection (GAPC)
• Secondary system supervision
- Current circuit supervision (RDIF)
- Fuse failure supervision (RFUF)
• Control
- Synchrocheck and energizing check (RSYN, 25)
- Apparatus control for single bay, max 8 app.(1CB) incl. Interlocking (APC8)
- Apparatus control for single bay, max 15 app.(2CBs) incl. Interlocking (APC15)
- Apparatus control for up to 6 bays, max 30 app. (6CBs) incl. Interlocking (APC30)
• Logic
- Tripping logic (PTRC, 94)
- Trip matrix logic
- Configurable logic blocks
- Fixed signal function block
• Monitoring
- Measurements (MMXU)
- Supervision of mA input signals (MVGGIO)
- Event counter (GGIO)
- Event function
- Disturbance report (RBDR)
• Metering
- Pulse counter logic (GGIO)
• Station communication
- IEC61850-8-1 communication
- LON communication protocol
- SPA communication protocol
- IEC 60870-5-103 communication protocol
- Horizontal communication via GOOSE for interlocking
- Single command, 16 signals
- Multiple Command, 80 blocks with 16 signals each
- Ethernet configuration of links
• Remote communication
- Binary signal transfer
• Basic IED functions
- Self supervision with internal event list
- Time synchronization (TIME)
- Parameter setting groups
- Test mode functionality (TEST)
- Change lock function
- IED identifiers
- Rated system frequency
• Hardware
- Power supply module (PSM)
- Binary input module (BIM)
- Binary output module (BOM)
- Binary in/out module (IOM)
- mA input module (MIM)
- Transformer input module, standard compression connection terminals (TRM)
- Optical ethernet module (OEM)
- SPA/LON/IEC module (SLM)
- Line data communication module (LDCM)
- GPS time synchronization module (GSM)
• Accessories
- GPS antenna, including mounting kit
- External interface converter from C37.94 to G703
- High impedance resistor unit
- Test switch module RTXP24
- On/off switch