Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

A-B 1747-AENTR Install Your Adapter SLC 500 EtherNet/IP Adapter

From:A-B | author:Mr.Chen | Time :2024-12-14 | 1614 view: | 🔊 Click to read aloud ❚❚ | Share:

The network address switches are set to 999 and DHCP enabled, by default.

You can set the network Internet Protocol (IP) address in the following ways:

• Use the network address switches on the module.

• Use a Dynamic Host Configuration Protocol (DHCP) server, such as

Rockwell Automation BootP/DHCP.

• Retrieve the IP address from nonvolatile memory.

The adapter reads the network address switches first to determine if the

switches are set to a valid number. You set the node address by using the

network address switches. Valid settings range from 001…254.

When the switches are set to a valid number, the adapter’s IP address is

192.168.1.xxx (where xxx represents the number set on the switches).

The adapter’s subnet mask is 255.255.255.0 and the gateway address is set to

0.0.0.0. The adapter does not have a host name assigned, or use any Domain

Name System when using the network address switch settings.

If the switches are set to an invalid number (for example, 000 or a value greater

than 254 excluding 888), the adapter checks to see if DHCP is enabled. Setting

the switches to 888 restores default factory settings.

IMPORTANT If you set the value of the adapter switch to 888 and then power cycle

the module, the following occurs:

• The DHCP Enabled function is enabled (set to True).

• The Ethernet link is negotiated automatically. The Auto Negotiate

function is set to True.

• The web server is enabled. The Disabled Web Server function is

disabled.

• The Ethernet ports are disabled. Both ports are re-enabled once the

switches are returned to their previous value and power is cycled.

Enable or Disable the Web Server

Enable Web Server in Static IP mode

1. Set the switches to 000 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

the message “Web Server Enabled”.

2. Set the switches to the desired IP address and cycle power to the adapter.

3. In your web browser, enter the IP address of the adapter.

The web server home page displays.

Disable Web Server in Static IP mode

1. Set the switches to 901 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

the message “Web Server Disabled”.

2. Set the switches to the desired IP address and cycle power to the adapter.

3. In your web browser, enter the IP address of the adapter.

The web server home page does not display.

Enable Web Server in DHCP mode

Before you begin, verify that you have an active DHCP server on your network.

1. Set the switches to 000 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

the message “Web Server Enabled”.

2. Set the switches to 999 and cycle power to the adapter.

3. In RSLinx software, check the IP address that was assigned to the

adapter by the DHCP server and verify the connection.

4. In your web browser, enter the IP address of the adapter.

The web server home page displays.

Disable Web Server in DHCP mode

Before you begin, verify that you have an active DHCP server on your network.

1. Set the switches to 901 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

the message “Web Server Disabled”.

2. Set the switches to 999 and cycle power to the adapter.

3. In RSLinx software, check the IP address that was assigned to the

adapter by the DHCP server and verify the connection.

4. In your web browser, enter the IP address of the adapter.

The web server home page does not display.

Enable Web Server in User-set IP mode

1. Set the switches to 000 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

the message “Web Server Enabled”.

2. Set the switches to 999 and cycle power to the adapter.

3. In RSLinx software, change the Port Configuration setting to “Manual

IP”, set the desired IP address, and cycle power to the adapter.

4. In your web browser, enter the IP address of the adapter.

The web server home page displays.

Disable Web Server in User-set IP mode

1. Set the switches to 901 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

  • ICS TRIPLEX TC-201-02-4M5 Trusted I/O Companion Slot Cable
  • ICS Triplex TC-301-02-4M5 Local Expansion Cable Supplier
  • ICS TRIPLEX TC-314-03-xmx Expander Electrical Extension Cable (UL)
  • ICS TRIPLEX TC-314-02-xmx Expander Electrical Extension Cable
  • ICS TRIPLEX TC-313-03-xmx Local Expansion Cable Assembly
  • ICS TRIPLEX TC-313-02-xmx Local Expansion Cable Assembly
  • ICS TRIPLEX TC-312-03-xmx Local Expansion Cable Assembly
  • ICS TRIPLEX TC-312-02-xmx Local Expansion Cable Assembly
  • ICS TRIPLEX TC-311-03 Local Expansion Cable Assembly
  • ICS TRIPLEX TC-311-02 Local Expansion Cable Assembly
  • ICS TRIPLEX TC-310-03 Output Smart Slot Jumper Cable
  • ICS TRIPLEX TC-310-02 Output Smart Slot Jumper Cable from Digital Output Module (T8472)
  • ICS TRIPLEX TC-308-03 Output Smart Slot Jumper Cable (UL)
  • ICS TRIPLEX TC-308-02 Output Smart Slot Jumper Cable
  • ICS TRIPLEX TC-306-03 Input Smart Slot Jumper Cable (UL)
  • ICS TRIPLEX TC-306-02 Input Smart Slot Jumper Cable
  • ICS TRIPLEX TC-305-01 Communications Cable Assembly
  • ICS TRIPLEX TC-304-01 Maintenance Cable
  • ICS TRIPLEX TC-303-03-xmx Remote Expansion Cable (UL)
  • ICS TRIPLEX TC-303-02-xmx Remote Expansion Cable
  • ICS TRIPLEX TC-302-03-xmx Remote Expansion Cable (UL)
  • ICS TRIPLEX TC-302-02-xmx Remote Expansion Cable
  • ICS TRIPLEX TC-301-03-xmx Local Expansion Cable (UL)
  • ICS TRIPLEX TC-301-02-xmx Local Expansion Cable
  • ICS Triplex T9882 Analogue Output TA,8 Channel,Dua
  • ICS TRIPLEX T9482 Analogue output module
  • ICS TRIPLEX T3510 - High-Reliability IO Power Supply Module
  • ICS TRIPLEX FAIR-RITE VO controller module
  • ICS TRIPLEX 1433/09232486825 Terminal module
  • ICS Triplex T8461C | Trusted® Digital Output Module
  • ICS TRIPLEX 151661 Industrial Control Module
  • ICS TRIPLEX T9310-02 Off-the-Shelf Module
  • ICS Triplex T9481 Analoque output module
  • ICS TRIPLEX T8300 | Trusted TMR Expansion Chassis
  • ICS TRIPLEX TC-305-01-5M0 Trusted Communications Cables
  • ICS TRIPLEX TC-303-01-2M0 Trusted Communications Cables
  • ICS TRIPLEX TC-201-01-4M5 Trusted Communications Cables
  • ICS TRIPLEX TC-215-01-6M5 Trusted Communications Cables
  • ICS TRIPLEX TC-215-01-4M5 Trusted Communications Cables
  • ICS TRIPLEX TC-201-01-6M5 Trusted Communications Cables
  • ICS TRIPLEX TC-301-02-2M0 Trusted Communications Cables
  • ICS TRIPLEX TC-801-02-4M5 Controller Module Card
  • ICS Triplex T8850 Trusted 40 Channel Analogue or Digital Output FTA
  • ICS Triplex T8100 Trusted TMR Controller Chassis
  • ICS Triplex T8193 Trusted Shield Module
  • ICS TRIPLEX T8191 PLC Controller Module Card Transmitter Sensor
  • ICS TRIPLEX 9100 Off-the-Shelf Modules
  • ICS TRIPLEX T8312-4 Trusted TMR Expander Interface Adapter Unit
  • ICS TRIPLEX T8431 Analog Input Module - 40 Channel
  • ICS TRIPLEX T8431 Analog Input Module - 40 Channel
  • ICS Triplex T9432 Analog Input module
  • ICS Triplex T8310 Trusted TMR Expander Processor
  • T8403 | ICS Triplex | Trusted TMR 24V dc Digital Input Module
  • ICS TRIPLEX T9451 24VDC Fault-Tolerant Output Module
  • ICS TRIPLEX 9300 | TMR PLC Module / I/O Backplane
  • ICS TRIPLEX T8110 Trusted TMR Processor
  • ICS TRIPLEX T8110B Trusted TMR Processor
  • ICS TRIPLEX T19109300680460 Base
  • ICS TRIPLEX T19109100710010 Base
  • ICS Triplex T9402 AADvance Controller 16 Channel Digital Input Module
  • IBA ibaFOB-2i-D PCI cards
  • IBA IBAFOB-4I-S PCl Interface Boards
  • IBA ibaCom-L2B-8-8 PROFIBUS Interface PCI Board
  • IBA ibaCom-L2B-4-8 PROFIBUS Interface PCI Board
  • MITSUBISHI A1SJ51T64 MELSEC-I/O Link Remote I/O System Master Module
  • MITSUBISHI HC-KFS23K - AC servo motors
  • MITSUBISHI ST1X4-DE1 - I-O Units
  • Hirschmann Belden EAGLE40-07 field-level industrial firewall
  • Hirschmann Belden EAGLE40-03 field-level industrial firewall
  • Hirschmann Belden EAGLE40-4F field-level industrial firewall
  • Hirschmann mm3-4flm4 mice media module
  • Hirschmann Mm4-2Tx/Sfp Mice Media Module
  • Hirschmann MS4128-L2P Power Switching Module
  • Hirschmann Mini-UTDE 10 BASE-T Industrial Ethernet Switch
  • MM20-Z6Z6Z6Z6SBH Hirschmann Industrial Ethernet Switch
  • MTM8000-4QSFP28-A - MAMMUTHUS Media Module for MTS8000 Series Switch
  • Hirschmann 942170-077 BRS40-12TX Gigabit Ethernet Switch
  • BRS50-00122Q2Q Hirschmann Switch Ethernet công nghiệp có quản lí 8 cổng 10/100/1000M
  • BRS50-20TX/4SFP - 942 170-071 Managed 24 port Gigabit Switch with 20 GTX + 4GE/2.5G SFP ports, TSN
  • Compra Switch Hirschmann Gigabit Ethernet BRS50-00122Q2Q-TTCZ99HHSESXX.X.XX
  • BRS40-00169999-STCY99HHSESXX.X.XX | Hirschmann Managed Switch 16 Port Ethernet Switch
  • BRS40-16TX/4SFP-EEC - 942 170-066 Managed 20 port Gigabit Switch with 16 GTX + 4GE SFP ports
  • Hirschmann 942170-092 BRS40-24TX-EEC Gigabit Ethernet Switch
  • BRS40-0024OOOO-STCZ99HHSEA - 942170999-40H - Managed 24-port Switch
  • BRS40-8TX/4SFP (942170009) | HIRSCHMANN BOBCAT Switch 12-port
  • 943376001 SPIDER 8TX | Hirschmann DIN Rail Mount Unmanaged Ethernet Switch, 8 RJ45 Ports | RS
  • BRS30-20TX-EEC Switch công nghiệp 16 cổng 100M Ethernet, 4 cổng 10000M Ethernet
  • Hirschmann BOBCAT 20xTX BRS30-16042T2T-CTCY99HHSE
  • Belden Bobcat BRS30-0804OOOO-STCZ99HHSES | Industrial Ethernet Switches
  • BOBCAT Next-Generation Compact Managed Switches - Hirschmann
  • Hirschmann BRS30-08042T2T-TTCX99HHSES BOBCAT Managed Switch
  • BRS30-16TX/4SFP - 942 170-059 Managed 20 port FE/GE Switch with 16TX + 4GE SFP ports, TSN
  • BRS30-12TX-EEC Switch công nghiệp 12 cổng 100M Ethernet
  • Honeywell PEC8445-PB1-SO programmable unitary controller
  • Honeywell PEC8445-PB1-SM programmable unitary controller
  • Honeywell PRO32E2EN Network Kits
  • Honeywell PRO32E1EN Network Kits
  • Honeywell PRO32E1PS Optional Accessories
  • Honeywell PRO22DCC Optional Accessories
  • Honeywell PRO32E1D8 PRO3200 Expansion Kits
  • Honeywell PRO32E1D4 PRO3200 Expansion Kits
  • Honeywell PRO32E1D2 PRO3200 Expansion Kits
  • Honeywell PRO32SKD8 PRO3200 Starter Kit with Software
  • Honeywell PRO22ENC5 Professional Series Access Enclosure
  • Honeywell PRO22ENC4 Professional Series Access Enclosure
  • Honeywell PRO22ENC3 Professional Series Access Enclosure
  • Honeywell PRO22ENC2 Professional Series Access Enclosure
  • Honeywell PRO22ENC1 Professional Series Access Enclosure
  • Honeywell PRO32IN PRO3200 16 Alarm Input Module
  • Honeywell PRO32OUT PRO3200 16 Relay Output Module
  • Honeywell PRO32R2 PRO3200 Dual Reader Module
  • Honeywell PRO22R1 PRO2200 Single Reader Module
  • Honeywell PRO32IC PRO3200 Intelligent Controller
  • Honeywell PUC00016-EM2 I/O expansion module DOx16
  • Honeywell PUC16000-EM2 I/O expansion module UIx16
  • Hirschmann BOBCAT 16xTX, 4xSFP BRS30-1604OOOO-CTCY99HHSEA
  • Hirschmann 942170-085 BRS30-20TX Gigabit Ethernet Switch
  • Hirschmann 942170-017 BRS30-8TX/4SFP-EEC Ethernet Switch
  • BRS20-2400ZZZZ-SFCZ99HHSEAXX.X.XX | HIRSCHMANN Industrial Managed
  • Hirschmann 942170-003 BRS20-4TX/2FX Ethernet Switch
  • BRS20-12TX - Hirschmann - Switch, 12 Ports, Industrial
  • Hirschmann BRS20 BRS20-8TX BOBCAT Rail Switch
  • BRS20-2400ZZZZ-TTDY99HHSESXX.X.XX Hirschmann | Switch Ethernet Hirschmann
  • 6 Ports Hirschmann BRS20-4TX Managed Industrial Network Switch
  • Hirschmann BRS20-8TX Ethernet Switch
  • Hirschmann 942170-081 BRS20-20TX Ethernet Switch
  • BRS20-8TX/2FX - Hirschmann - Switch, BOBCAT, 10 Ports
  • Hirschmann Belden EAGLE4-07206 Next-Generation Firewall with Stateful/Deep Packet Inspection and IPSec VPN