Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

A-B 1747-AENTR Install Your Adapter SLC 500 EtherNet/IP Adapter

From:A-B | author:Mr.Chen | Time :2024-12-14 | 2733 view: | 🔊 Click to read aloud ❚❚ | Share:

The network address switches are set to 999 and DHCP enabled, by default.

You can set the network Internet Protocol (IP) address in the following ways:

• Use the network address switches on the module.

• Use a Dynamic Host Configuration Protocol (DHCP) server, such as

Rockwell Automation BootP/DHCP.

• Retrieve the IP address from nonvolatile memory.

The adapter reads the network address switches first to determine if the

switches are set to a valid number. You set the node address by using the

network address switches. Valid settings range from 001…254.

When the switches are set to a valid number, the adapter’s IP address is

192.168.1.xxx (where xxx represents the number set on the switches).

The adapter’s subnet mask is 255.255.255.0 and the gateway address is set to

0.0.0.0. The adapter does not have a host name assigned, or use any Domain

Name System when using the network address switch settings.

If the switches are set to an invalid number (for example, 000 or a value greater

than 254 excluding 888), the adapter checks to see if DHCP is enabled. Setting

the switches to 888 restores default factory settings.

IMPORTANT If you set the value of the adapter switch to 888 and then power cycle

the module, the following occurs:

• The DHCP Enabled function is enabled (set to True).

• The Ethernet link is negotiated automatically. The Auto Negotiate

function is set to True.

• The web server is enabled. The Disabled Web Server function is

disabled.

• The Ethernet ports are disabled. Both ports are re-enabled once the

switches are returned to their previous value and power is cycled.

Enable or Disable the Web Server

Enable Web Server in Static IP mode

1. Set the switches to 000 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

the message “Web Server Enabled”.

2. Set the switches to the desired IP address and cycle power to the adapter.

3. In your web browser, enter the IP address of the adapter.

The web server home page displays.

Disable Web Server in Static IP mode

1. Set the switches to 901 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

the message “Web Server Disabled”.

2. Set the switches to the desired IP address and cycle power to the adapter.

3. In your web browser, enter the IP address of the adapter.

The web server home page does not display.

Enable Web Server in DHCP mode

Before you begin, verify that you have an active DHCP server on your network.

1. Set the switches to 000 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

the message “Web Server Enabled”.

2. Set the switches to 999 and cycle power to the adapter.

3. In RSLinx software, check the IP address that was assigned to the

adapter by the DHCP server and verify the connection.

4. In your web browser, enter the IP address of the adapter.

The web server home page displays.

Disable Web Server in DHCP mode

Before you begin, verify that you have an active DHCP server on your network.

1. Set the switches to 901 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

the message “Web Server Disabled”.

2. Set the switches to 999 and cycle power to the adapter.

3. In RSLinx software, check the IP address that was assigned to the

adapter by the DHCP server and verify the connection.

4. In your web browser, enter the IP address of the adapter.

The web server home page does not display.

Enable Web Server in User-set IP mode

1. Set the switches to 000 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

the message “Web Server Enabled”.

2. Set the switches to 999 and cycle power to the adapter.

3. In RSLinx software, change the Port Configuration setting to “Manual

IP”, set the desired IP address, and cycle power to the adapter.

4. In your web browser, enter the IP address of the adapter.

The web server home page displays.

Disable Web Server in User-set IP mode

1. Set the switches to 901 and cycle power to the adapter.

The module LED flashes red and the four-character status display scrolls

  • Beckhoff ELX3152-0090 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELX3158 | EtherCAT Terminal, 8-channel analog input, current, 4…20 mA
  • Beckhoff ELX3152 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3704-1001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0020 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3702-0101 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3702-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3604-0002 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3604-0000 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0032 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0030 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0002 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0000 | EtherCAT Terminal, 2-channel analog input
  • Beckhoff ELM3544-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3542-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • ENOTEC GAS ANALYZER SYSTEM OXITEC 5000 SME-53310000
  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch
  • Eaton 5884-1400 6-Digit Dual Preset Control W/ Batch Control
  • Eaton 1023843 Power Circuit Board 94V
  • EATON ES4P-221-DRXD1 24VDC NSMP
  • Eaton DH222NWK heavy duty fusible safety switch
  • Eaton Touch Panel 10.1 inch XV-303-10-C00-A00-1C
  • Eaton RDF200J-3 Bussmann series RDF fused rotary disconnect switch
  • EATON CORPORATION A200M2CACD A200 NEMA Motor Control
  • Eaton SPD160208Y3J Surge Protection Device
  • EATON CORPORATION SPD160208Y3K SURGE SUPPRESSOR
  • EATON DILM400/22 (RA250) 200KW Coil Voltage/Coil 110-250V 40-60Hz/DC
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • EATON CORPORATION D820MPM HMI
  • EATON PXG900 Power Xpert Insight Gateway 900
  • Eaton Durant 5882-7 Digital Counter loc2D3
  • EATON AXCELIS 1220-0012-0002 DISK VACUUM DI CONTROLLER
  • Eaton 1383B-6501 80 Series Photoelectric Sensor Head
  • Eaton FDC2100L Series C molded case switch
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • Eaton FD3200L circuit breaker
  • Eaton Touch Screen Control Panel X-152-D6-10TVRC-10
  • EATON VICKERS EEA-PAM-523-A-32 02-326001 POWER AMPLIFIER
  • Saacke Seavis HMI 03 EATON XV-102-B6-35TQR-1AL-PLC HMI Touch Panel
  • EATON MTL E05016 DIGITAL INPUT EUROCARD E05516-2134
  • Eaton HFD3150 3P 150A 600VAC Circuit Breaker
  • Eaton HMIVU06CUNB1 HMi Operator Interface, RS-232, 5.6"
  • Cutler-Hammer/ Eaton Panelmate PowerPro 5785 with cables LCD monitor
  • Eaton D100CA40 40 I/O Micro PLC 115VAC Input Triac Output
  • EATON CUTLER HAMMER 66D2032GX1 MP-3000 PROTECTION RELAY
  • EATON R9L3200FJ Rotary Disconnect Switch
  • EATON CORPORATION E51CLT16PCU Switch
  • Aerotech Modular System Control Console
  • Aerotech TV Series Transformers
  • Aerotech TM5 Transformer Module (500 watts)
  • Aerotech TM3 Transformer Module
  • Aerotech UFM Noise Filter Module
  • Aerotech MFM10-2 Motor filter module
  • Aerotech MFM10-1 Motor filter module
  • Aerotech MPG Handwheel Pendant
  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3246-0000 | EtherCAT Terminal, 6-channel analog input, temperature
  • Beckhoff ELM3244-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3148-0000 | EtherCAT Terminal, 8-channel analog input, multi-function
  • Beckhoff ELM3146-0000 | EtherCAT Terminal, 6-channel analog input, multi-function
  • Beckhoff ELM3144-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckwith Electric M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-3919A Graphic Display Unit/ Human Machine Interface
  • Beckwith Electric M-4172 Digital Motor Bus Transfer System
  • Beckwith Electric M-3904B Remote Monitoring Module
  • Beckwith Electric M-3410A Intertie/Generator Protection Relay
  • Beckwith Electric B-1612 Adapter
  • Beckwith Electric B-1652 Adapter
  • Beckwith Electric B-1685 Adapter
  • Beckwith Electric M-2035 Analog to Digital Interface Module
  • Beckwith Electric B-2291 Digital Input Guard
  • Beckwith Electric M-2406 Recloser Control Adapter Chassis
  • Beckwith Electric M-3908 Universal Contact Input Adapter
  • Beckwith Electric M-3801D IPS Plot Software
  • Beckwith Electric M-7651A D-PAC
  • Beckwith Electric M-2979 Recloser Control Cabinet
  • Beckwith Electric M-0359 SYNCROCLOSER MOD512
  • Beckwith Electric M-2001C-6ELFA Tap Changer Controller Voltage Regulator Control
  • Beckwith Electric M-0124 TERMINAL BOARD ADAPTER PLATE 13 POS
  • Beckwith Pride M-0296C 3ph Programmable Relay