Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

A-B 1746-HSCE2 Multi-Channel High-Speed Counter

From:A-B | author:Mr.Chen | Time :2024-11-28 | 753 view: | 🔊 Click to read aloud ❚❚ | Share:

Hardware Features 

The module’s hardware features are illustrated below.

Installing the Module

1. Make sure your SLC power supply has adequate reserve current capacity.

The  module requires 250 mA at +5V dc. 

2. Align the full-sized circuit board with the chassis card guide as shown below.

The first slot of the first chassis is reserved for the processor.

3. Slide the module into the chassis until the top and bottom latches catch. 

To  remove the module, press the release clips at the top and bottom of the module  and slide it out. 

4. Cover all unused card slots with the Card Slot Filler, catalog number 1746-N2.

Important Wiring Considerations

Use the following guidelines when planning the system wiring for the module:

• Install the SLC 500 system in a NEMA-rated enclosure.

• Disconnect power to the SLC processor and the module before wiring.

• Make sure the system is properly grounded.

• Group this module and low-voltage DC modules away from AC I/O or 

high-voltage DC modules.

• Shielded cable is required for high-speed input signals A, B, and Z. Use 

individually shielded, twisted pair cable lengths up to 300 m (1000 ft.).

• Shields should be grounded only at one end. Ground the shield wire outside 

the module at the chassis mounting screw. Connect the shield at the encoder 

end only if the housing is isolated from the motor and ground.

• If you have a junction in the cable, treat the shields as a conductor at all 

junctions. Do not ground them to the junction box.

Considerations for Reducing Noise

In high noise environments, the 1746-HSCE2 inputs may accept “false” pulses, 

particularly when using low frequency input signals with slowly sloping pulse 

edges. To minimize the effects of high frequency noise on low frequency signals, 

the user can do the following:

• Identify and remove noise sources.

• Route 1746-HSCE2 input cabling away from noise sources.

• Install low pass filters on input signals. Filter values are dependent on the 

application and can be determined empirically.

• Use devices which output differential signals, like differential encoders, to 

minimize the possibility that a noise source will cause a false input.

Electronic Protection

The electronic protection of the 1746-HSCE2 has been designed to provide 

protection for the module from short-circuit and overload current conditions. The 

protection is based on a thermal cut-out principle. In the event of a short circuit or 

overload current condition on an output channel, all channels turn off within 

milliseconds after the thermal cut-out temperature has been reached. 

IMPORTANT

The module does not provide protection against reverse 

polarity wiring or wiring to AC power sources. Electronic 

protection is not intended to replace fuses, circuit breakers, or 

other code-required wiring protection devices.

Auto Reset Operation

IMPORTANT

1746-HSCE2 outputs perform auto-reset under overload 

conditions. When an output channel overload occurs as 

described above, all channels turn off within milliseconds 

after the thermal cut-out temperature has been reached. While 

the overcurrent condition is present, the module tries resetting 

the outputs at intervals of 500 ms. If the fuse cools below the 

thermal cut-out temperature, all outputs will auto-reset and 

resume control of their external loads as directed by the 

module until the thermal cut-out temperature is again reached.

Removing power from an overloaded output channel would 

also allow the fuse to cool below the thermal cut-out 

temperature, allowing auto-reset to occur when power is 

restored. The output channel then operates as directed by the 

module until the thermal cut-out temperature is again reached.

To avoid auto-reset of output channels under overload 

conditions, monitor the fuse blown status bit (FB1) in the 

module’s status file and latch the output off when an 

overcurrent condition occurs. An external mechanical fuse 

can also be used to open an output circuit when it is 

  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch
  • Eaton 5884-1400 6-Digit Dual Preset Control W/ Batch Control
  • Eaton 1023843 Power Circuit Board 94V
  • EATON ES4P-221-DRXD1 24VDC NSMP
  • Eaton DH222NWK heavy duty fusible safety switch
  • Eaton Touch Panel 10.1 inch XV-303-10-C00-A00-1C
  • Eaton RDF200J-3 Bussmann series RDF fused rotary disconnect switch
  • EATON CORPORATION A200M2CACD A200 NEMA Motor Control
  • Eaton SPD160208Y3J Surge Protection Device
  • EATON CORPORATION SPD160208Y3K SURGE SUPPRESSOR
  • EATON DILM400/22 (RA250) 200KW Coil Voltage/Coil 110-250V 40-60Hz/DC
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • EATON CORPORATION D820MPM HMI
  • EATON PXG900 Power Xpert Insight Gateway 900
  • Eaton Durant 5882-7 Digital Counter loc2D3
  • EATON AXCELIS 1220-0012-0002 DISK VACUUM DI CONTROLLER
  • Eaton 1383B-6501 80 Series Photoelectric Sensor Head
  • Eaton FDC2100L Series C molded case switch
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • Eaton FD3200L circuit breaker
  • Eaton Touch Screen Control Panel X-152-D6-10TVRC-10
  • EATON VICKERS EEA-PAM-523-A-32 02-326001 POWER AMPLIFIER
  • Saacke Seavis HMI 03 EATON XV-102-B6-35TQR-1AL-PLC HMI Touch Panel
  • EATON MTL E05016 DIGITAL INPUT EUROCARD E05516-2134
  • Eaton HFD3150 3P 150A 600VAC Circuit Breaker
  • Eaton HMIVU06CUNB1 HMi Operator Interface, RS-232, 5.6"
  • Cutler-Hammer/ Eaton Panelmate PowerPro 5785 with cables LCD monitor
  • Eaton D100CA40 40 I/O Micro PLC 115VAC Input Triac Output
  • EATON CUTLER HAMMER 66D2032GX1 MP-3000 PROTECTION RELAY
  • EATON R9L3200FJ Rotary Disconnect Switch
  • EATON CORPORATION E51CLT16PCU Switch
  • Aerotech Modular System Control Console
  • Aerotech TV Series Transformers
  • Aerotech TM5 Transformer Module (500 watts)
  • Aerotech TM3 Transformer Module
  • Aerotech UFM Noise Filter Module
  • Aerotech MFM10-2 Motor filter module
  • Aerotech MFM10-1 Motor filter module
  • Aerotech MPG Handwheel Pendant
  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3246-0000 | EtherCAT Terminal, 6-channel analog input, temperature
  • Beckhoff ELM3244-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3148-0000 | EtherCAT Terminal, 8-channel analog input, multi-function
  • Beckhoff ELM3146-0000 | EtherCAT Terminal, 6-channel analog input, multi-function
  • Beckhoff ELM3144-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckwith Electric M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-3919A Graphic Display Unit/ Human Machine Interface
  • Beckwith Electric M-4172 Digital Motor Bus Transfer System
  • Beckwith Electric M-3904B Remote Monitoring Module
  • Beckwith Electric M-3410A Intertie/Generator Protection Relay
  • Beckwith Electric B-1612 Adapter
  • Beckwith Electric B-1652 Adapter
  • Beckwith Electric B-1685 Adapter
  • Beckwith Electric M-2035 Analog to Digital Interface Module
  • Beckwith Electric B-2291 Digital Input Guard
  • Beckwith Electric M-2406 Recloser Control Adapter Chassis
  • Beckwith Electric M-3908 Universal Contact Input Adapter
  • Beckwith Electric M-3801D IPS Plot Software
  • Beckwith Electric M-7651A D-PAC
  • Beckwith Electric M-2979 Recloser Control Cabinet
  • Beckwith Electric M-0359 SYNCROCLOSER MOD512
  • Beckwith Electric M-2001C-6ELFA Tap Changer Controller Voltage Regulator Control
  • Beckwith Electric M-0124 TERMINAL BOARD ADAPTER PLATE 13 POS
  • Beckwith Pride M-0296C 3ph Programmable Relay
  • Beckwith Electric M-0388 Syncrocloser Check Relay
  • M-0170A AC Current Relay Beckwith Electric
  • Beckwith Electric Intertie Protection M-3520 Instruction Manual
  • M-3311 M-3311 7113 BECKWITH ELECTRIC TRANSFORMER PROTECTION RELAY
  • Pride M-0296b 3 phase Programmable Relay Beckwith Electric Co
  • Beckwith Electric M3310 Integrated Transformer Protection Panel
  • Beckwith M-0145 First Customer Protector
  • Beckwith Electric M-0296C 3 phase Programmabel Relay
  • Beckwith Electric M-0389 VOLTAGE VERIFIER
  • M-3425 M-3425-A1DE BECKWITH ELECTRIC GENERATOR PROTECTION RELAY SL
  • Beckwith Electric M-0420 Multifunction Relay Protection Module 48VDC
  • M-3430 M-3430M0D515 BECKWITH ELECTRIC GENERATOR PROTECTION RELAY
  • Beckwith Electric Tapchanger Control M-0067E
  • Beckwith M-2001D-6L4S20C0S0X Tap Changer Control Surplus
  • BECKWITH ELECTRIC M3425A-STD1 Generator Protection 85-280VDC
  • Beckwith Electric High Speed Sync-Check Relay #M-0245C Mod #22 (NIB)
  • Beckwith Electric M-7679 R-PAC
  • Beckwith Electric TAPCHANGER CONTROL M-2001C-6SL