Watlow’s New WATCONNECT® Large and Extra-Large Panels Maximize
Process Uptime with Small Footprint
Watlow’s new WATCONNECT® large and extra-large control panels
are designed to maximize process uptime with a small footprint.
Unlike most control panels installed in the field, WATCONNECT large
and extra-large control panels permit safe access to control compartments
allowing users to troubleshoot without shutting down the process.
In addition, the large and extra-large panels only require 50% of the
space of competitive panels, which frees up areas for other critical
equipment needed in the process.

As an additional option, the Data Insights Package offers remote monitoring
to the cloud of thermal system analytics such as power and control health,
failed element detection, process continuity and more.
All WATCONNECT control panels are pre-designed for a proven, high-quality
solution.
Features and Benefits
Advanced thermal design
• Offers high reliability
• Includes solid copper internal power interconnect for less expansion and contraction
• Provides environmental and field connection health monitoring for identifying
issues before shutdown
Easy access to control compartment
• Allows for panel troubleshooting without process shutdown
Resettable components
• Reduces maintenance time
• Eliminates need for spare parts
Small footprint
• Utilizes up to 50% less control room space than other panels
Data Insights Package (optional) - Industry 4.0
• Allows for remote review and analysis of the data collected by a data scientist
and thermal system expert
• Includes comprehensive quarterly thermal system report including insights and
recommendations for system improvement
• Offers collaborative touchpoints: Engineer-to-engineer data review
• Enables preventative maintenance or factory assistance
Specifications
Agency approvals
• North America:
• UL® / cUL® 508A Listed (non-hazardous area)
• NNNY Class I, Div II, Groups B/C/D (hazardous areas)
• NNNY Class I, Zone 2, Groups IIA, IIB, IIC
• Europe: Self-declared CE Safe Area to EN 602024 or EN
61439 directives without type testing
Models / Current Rating
• Large single bay – up to 720A Full Load Amps (800 mm
wide)
• XL two bay / two disconnect – up to 1440A FLA (1600 mm
wide)
• XL 3-7 bays / single disconnect – up to 4,320A FLA (2400 –
5800 mm wide)
Voltage Ratings (Three Phase)
• 230/240V, 380/400/415V, 440/460/480V, 575/600V, 690V
(50 or 60 Hz)
Enclosures
• Powder coated RAL 7035 or SS316 brush finish
• Each bay: 2000H x 800W x 600D (mm) + 200 mm plinth
(indoors) or +300 mm leg kit (outdoors)
Environmental UL® (CE)
• Type 1 (IP42), Type 4 (IP65) or Type 4X (IP65)
• Ambient up to 0°C to 40°C operating (without space heater)
• Ambient up to -18°C to 40°C (with space heater)
• Altitude <= 1000 mm without derate
Accessibility During Runtime
• Control compartment (allow access to components <=
120V)
• Fan compartment (allow access to components <= 120V)
• Hinged windows for branch MCCBs
Main Disconnect
• MCCB (300 – 1600A) or ACB (2500 – 5000A)
Feeder Field Wiring
• Wire sizes shown on quote schematic
Branch Protection
• MCCB (1-6 circuits per bay) or fuse (1-12 circuits per bay)
Load Field Wiring
• Wire sizes shown on quote and schematic
Internal Power Interconnect
• Insulated, stacked solid copper laminar bar (minimizes
expansion / contraction versus wire) for high reliability
Power Controllers
• Watlow ASPYRE® SCR 2 leg or 3 leg
• E-Power custom for load management and load shadding
Process Controllers
• Watlow F4T® controller, PM4 controller or none (with
4-20mA power level input from DCS)
Safety Shutdowns
• Heater upset (primary) – Watlow PM6 limit controller(s);
disconnects: Safety contactor
• Heater upset (secondary) – Limit controller communicates
status to process controller and DCS
• Remote DCS shutdown
• E-stop
• SCR overtemp, enclosure overtemp (optional), GFCI fault
(optional)
Cooling Options
• High reliability EC inlet and outlet fans
• N+1 variable speed high reliability EC fans with advanced
monitoring: Local and remote status, test button – 50%
longer lifetime rating than industry standard fans (60,000
hours)
• Air conditioner – powered internally or by others
Local Pilots
• Illumination:
• Control on/off
• Heater on/off
• E-Stop: With reset button for CE panels
• Over-temp: Push to reset
• Common alarm
• SCR fault: Push to reset (optional)
• GFCI fault: Push to reset (optional)
• Environmental fault: Push to reset (optional)
• Local / remote set point
DCS I/O
• Remote permissive / shutdown
• High limit alarm
• Common alarm
• Environmental failure (with monitoring option)
• Analog – remote set point
• Analog – process temperature re-transmit
Data Insights Package - Remote Diagnostics to the Cloud
• Power and temperature controller health
• Minimum data set: Current, voltage, power, leg balance,
SCR / controller alarms
• Field element detection
• Minimum data set: Current, voltage, power, leg balance,
SCR / controller alarms
• Process continuity (process drift)
• Minimum data set: Panel ambient temp, (if cooling) fan
control signal, fan RPM, fan life hours, (if heating) space
heater on/off, SCR internal temp, controller internal temp
• Optically decoupled monitoring of field wiring
• Minimum data set: Ambient temp, terminal temp, kW