10. Apply supply voltage, wait for self‑test completion (approx. 60 seconds).
> Clearance requirement: keep ≥10 cm top‑bottom ventilation space; left‑right ≥2 cm for RSP models. Device must be mounted vertically.
6. Power Supply Variants & Terminal Wiring Rules
RS20‑Basic power
- Dual redundant DC input: 9.6 V DC ~ 60 V DC, SELV. Non‑load‑sharing; device selects higher‑voltage source when dual power present. Single‑power input triggers fault‑relay alarm (can be disabled in management software).
| Code | Input range | Terminal type | Redundant |
|---|---|---|---|
| CC | 24‑48 V DC | 2‑pin | ✅ Dual input, ATEX‑approved power variant |
| TT | 12‑24 V DC | 2‑pin | ✅ Dual input |
| K9 | AC 110‑230 V / DC 60‑250 V | 3‑pin | ❌ Single input |
| KK | AC 110‑230 V / DC 60‑250 V | 3‑pin | ✅ Dual high‑voltage redundant input |
> Terminal torque spec: power terminals 0.51 Nm; signal‑contact terminals 0.34 Nm.
Fault‑signal relay contact
Potential‑free relay. Relay opens when alarm condition occurs: power‑supply failure, port link‑loss, ring‑redundancy fault, self‑test error.
Rating: max 1 A resistive load. For hazardous‑location deployment strictly follow entity‑parameter limits in control drawing.
7. LED Status Indicators
System LEDs
- Power: Green = all power inputs OK; Yellow = only one redundant source alive; Off = no valid supply. Blinking 4‑times‑per‑cycle = firmware upgrade in progress (do NOT cut power).
- FAULT(RS20‑Basic) / Status(RSP): Red light = system alarm / fault‑relay triggered.
- RM (RSP‑only): Ring‑manager LED for MRP / ring‑redundancy status.
Per‑port LED (LS link‑status, DA / ACT data‑activity)
- LS green solid: link up; blink = port standby / port disabled.
- DA / ACT yellow flicker: data transmit / receive traffic.
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2026 Cld , All Rights Reserved K-JIANG All rights reserved