Safety instructions
General safety instructions
You operate this device with electricity. Improper usage of the device
entails the risk of physical injury or significant property damage. The
proper and safe operation of this device depends on proper handling
during transportation, proper storage and installation, and careful
operation and maintenance procedures.

Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.
The device is free of any service components. In case of a damaged
or malfunctioning device, turn off the supply voltage and return the
device to Hirschmann for inspection.
Certified usage
Use the device solely for the application cases described in the
Hirschmann product information, including this manual.
Operate the device solely according to the technical specifications.

Installation site requirements
Install the device in a fire enclosure according to IEC 60950-1.
If installed in a living area or office environment, the device must be
operated only in switch cabinets with fire protection characteristics
according to IEC 60950-1.
Only when using the PoE power supply unit RPS90/48V HV:
Install this device only in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
Strain relief
Note: If the strain relief is insufficient, there is a potential risk of torsion,
contact problems and creeping interruptions.
Relieve the connection points of cables and lines from mechanical
stress.
Design strain reliefs in such a way that they help prevent any
mechanical damage to cables, wires or conductors caused by external
influences or their own weight.
To help prevent damage to device connections, connectors and
cables, follow the instructions for proper installation in accordance with
DIN VDE 0100-520:2013-06. sections 522.6. 522.7 and 522.13.
Device casing
Only technicians authorized by the manufacturer are permitted to open
the casing.
Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not
touch the connection terminals.
Keep the ventilation slits free to ensure good air circulation.
See “General technical data” on page 64.
Mount the device in the vertical position.
At ambient air temperatures > +60 °C (+140 °F):
The surfaces of the device housing may become hot. Avoid touching
the device while it is operating.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the
prerequisite for grounding and labeling circuits, devices, and systems
in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.
Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
National and international safety regulations
Verify that the electrical installation meets locally or nationally applicable
safety regulations.
Grounding the device
The device is grounded via the separate ground screw on the bottom left
of the front side of the device.
Use a wire diameter for the ground conductor that is no smaller than
the diameter of the supply voltage connection, however of at least 1.0
mm² (AWG16).
Ground the device before connecting any other cables.
Disconnect the grounding only after disconnecting all other cables.
Shielding ground
The overall shield of a connected shielded twisted pair cable is connected
to the grounding connector on the front panel as a conductor.
Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
Supply voltage
The supply voltage is electrically isolated from the housing.
The devices are designed for operation with Safety Extra-low Voltage
(SELV). Connect only SELV circuits with voltage restrictions according
to IEC 60950-1 or ES1 according to IEC/EN 62368-1 to the supply
voltage connections and to the signal contacts.
Exclusively connect a supply voltage that corresponds to the type
plate of your device.
Applies exclusively to RS20-..., RS30-..., RS40-... device variants:
For power supply via DC voltage: All following prerequisites are
fulfilled:
There are fuses suitable for DC voltage in the positive conductors
of the supply lines, or the voltage sources are appropriately current
limited. Regarding the properties of this fuse: See “General
technical data” on page 64.
The negative conductors of the voltage inputs are on ground
potential.
For power supply via AC voltage: All following prerequisites are
fulfilled:
There are fuses in the supply lines, or the voltage sources are
appropriately current-limited. Regarding the properties of this fuse:
See “General technical data” on page 64.
The power sources are electrically isolated from the ground
potential.
Description
You can choose from a wide range of variants. You have the option to set up
your device individually based on different criteria:
Number of ports
Transmission speed
Media type
Types of connectors
Temperature range
Certifications
Software variant
The device is designed for the special requirements of industrial automation.
The device meets the relevant industry standards, provides very high
operational reliability, even under extreme conditions, and also long-term
reliability and flexibility.
The device allows you to set up switched Industrial Ethernet networks
according to standard IEEE 802.3.
The device works without a fan.
The voltage is supplied redundantly.
The following installation options are available:
Mounting on the DIN rail
mounting them on a wall (only RS22/RS32)
Depending on the device variant, you can choose various media to connect
terminal devices and other infrastructure components:
Twisted pair cable
Multimode F/O
Singlemode F/O
The twisted pair ports support:
Autocrossing
Autonegotiation
Autopolarity
There are convenient options for managing the device. Manage your devices
via:
Web browser
Telnet
SSH
HiDiscovery (software for putting the device into operation)
Network management software (for example Industrial HiVision)
The Network Management Software Industrial HiVision provides you with
options for smooth configuration and monitoring. You find further
information on the Internet at the Hirschmann product pages:
http://www.hirschmann.com/en/QR/INET-Industrial-HiVision
V.24 interface (locally on the device)
The ring redundancy concept allows the network to be reconfigured quickly
after a failure.
Product configuration data can be provided by:
diagnosis displays
Display of the operating parameters
Label area for IP address
The device provides you with a large range of functions, which the manuals
for the operating software inform you about. You can download these
manuals as PDF files from the Internet at: https://www.doc.hirschmann.com
The Hirschmann network components help you ensure continuous
communication across all levels of the company.
Description of the device variants
The devices differ with regard to the range of software functions, the number
of interfaces, and the media type for connecting segments.
The table below shows three port categories for each product variant: uplink
ports, PoE ports and other ports. The table also shows for each product
category the number of ports you can select, and the type of ports. In the
column for the port type, the abbreviations F/O (optical fiber) and TP (twisted
pair) indicate the media type, while the abbreviations DSC, ST, SFP and
RJ45 indicate the socket type.