Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

ABB REM601 Motor protection and control

From:ABB | author:Mr.Chen | Time :2024-11-15 | 2534 view: | 🔊 Click to read aloud ❚❚ ▶ | Share:

REF601/REJ601 and REM601 are members of ABB’s Relion® protection and control product family and its 605 series.

These relays provide an optimised composition of protection, monitoring and control functionality in one unit,

with the best performance and usability in its class.

The relay REF601/REJ601 offers various application configurations for Feeder protection and control while 

REM601 offers application configurations for Motor protection and control.

Protection and control

REF601/REJ601 offer three-stage overcurrent and two-stage ground fault protection functions.

The low-set stages for overcurrent and ground fault protection are equipped with selectable characteristics

– Definite Time (DT) and Inverse Definite Minimum Time (IDMT).

The relay features standard IDMT characteristics according IEC 61255-3 - Normal Inverse, Very Inverse,

Extremely Inverse, Long-time Inverse.

They also feature characteristics according to ANSI C37.112 - Moderate Inverse, Normal Inverse, Very Inverse, Extremely Inverse.

The relay has a special

characteristic RI Inverse (RI) for better coordination with the rest of the network.

Additionally the relays also support two setting groups.

Thermal overload protection for feeder, cable and transformer,

negative phase sequence protection phase discontinuity protection and circuit breaker failure protection are also offered.

An auto-reclose function for overhead line feeders is optional.

The REM601 offers protections for motors such as thermal overload protection,

short circuit protection, startup supervision, loss-of-phase protection, negative phase sequence protection,

ground fault protection, undercurrent protection and circuit breaker failure protection.

An emergency restart feature allows motor start up even when start inhibit is activated.

The residual current for CT configured relays is derived from the phase currents.

When applicable the zero sequence CT can be used for measuring residual current especially when sensitive

ground fault protection is required.

The REF601 integrates basic control functionality.

Apart from display of data and parameter settings, the user friendly local

human-machine interface (LHMI) supports control of one circuit breaker with dedicated control push buttons.

The LHMI display has built in support for multiple languages.

All three relays are equipped with a three level, role-based user authentication system with individual passwords for the operator, engineer and administrator levels.

Ease of use

The pre-configured functionality of relay facilitates easy and fast commissioning of switchgear.

Three dedicated and five configurable LEDs indicate the status of relay and protection functions while the 

LCD displays measurements, settings, events and recorded data. The relay can be set-up and configured entirely from the local HMI or with PCM600.

A single wide range auxiliary supply eliminates the need for ordering variance.

The relays also boast a press-fit mounting design for effortless installations on panels.

Configurable inputs and outputs are included which can be easily altered by the LHMI.

These relays incorporate detachable terminals with CT shorting which aids in improving MTTR (Mean Time to Repair) thus

further reducing downtime and improving productivity.

Supervision

To ensure continuous availability of protection, self-supervision of the relay hardware and software is incorporated. The

REF601/REJ601 and REM601 also include an integrated trip-circuit monitoring function which monitors the external trip

signal path. A built-in test mode which enables users to test the relay HMI, protection functions, and binary outputs.

The 605 series relays can store 100 events with time stamps at a resolution of 1 ms.

They can also store analog fault records for the last five trip events.

This data is stored in non-volatile memory.

The optional communication card extends local monitoring and control facility of the HMI to remote automation systems over

MODBUS RTU / IEC 60870-5-103 protocol.

Sensor support

These relays support both conventional CTs and Rogowski current sensors.

The sensor option helps to obtain equipment size reduction, performance improvement and better standardization in compact MV switchgear.

  • Hirschmann RSPM-cover 942 131-001 Cover for RSPM modules
  • Hirschmann RSPM22-8TX-EEC 942 106-006 DIN Rail Mount Switches
  • Hirschmann RSPM20-8SFP Fast Ethernet media module for RSPE Switches
  • Hirschmann RSPM20-8SFP-EEC 942 106-005 DIN Rail Mount Switches
  • Hirschmann RSPM20-8TX-EEC 942 106-004 DIN Rail Mount Switches
  • Hirschmann RSPE37-8TX/4C-EEC-3S 942 084-006 DIN Rail Mount Switches
  • Hirschmann RSPE35-8TX/4C-EEC-2HV-3S 942 084-005 DIN Rail Mount Switches
  • Hirschmann RSPE32-8TX/4C-EEC-2A 942 084-004 DIN Rail Mount Switches
  • Hirschmann RSPE30-8TX/4C-EEC-2HV-3S 942 084-003 DIN Rail Mount Switches
  • Hirschmann RSPE30-8TX/4C-EEC-2HV-3S 942 084-003 DIN Rail Mount Switches
  • Hirschmann RSPE30-8TX/4C-2A 942 084-002 DIN Rail Mount Switches
  • Beckhoff EL4732 | EtherCAT Terminal, 2-channel analog output, voltage
  • Beckhoff EL4712 | EtherCAT Terminal, 2-channel analog output, current
  • Beckhoff ELX4184 | EtherCAT Terminal, 4-channel analog output, current
  • Beckhoff ELX4181 | EtherCAT Terminal, 1-channel analog output, current
  • Beckhoff ELX4154 | EtherCAT Terminal, 4-channel analog output, current
  • Beckhoff EL4134-0030 | EtherCAT Terminal, 4-channel analog output, voltage, ±10 V, 16 bit
  • Beckhoff EL4134 | EtherCAT Terminal, 4-channel analog output, voltage, ±10 V, 16 bit
  • Beckhoff EL4132 | EtherCAT Terminal, 2-channel analog output, voltage, ±10 V, 16 bit
  • Beckhoff EL4124 | EtherCAT Terminal, 4-channel analog output, current, 4…20 mA, 16 bit
  • Beckhoff EL4122 | EtherCAT Terminal, 2-channel analog output, current, 4…20 mA, 16 bit
  • Beckhoff EL4114 | EtherCAT Terminal, 4-channel analog output, current, 0…20 mA, 16 bit
  • Beckhoff EL4112-0010 | EtherCAT Terminal, 2-channel analog output, current, ±10 mA, 16 bit
  • Beckhoff EL4112 | EtherCAT Terminal, 2-channel analog output, current, 0…20 mA, 16 bit
  • Beckhoff EL4104 | EtherCAT Terminal, 4-channel analog output, voltage, 0…10 V, 16 bit
  • Beckhoff EL4102 | EtherCAT Terminal, 2-channel analog output, voltage, 0…10 V, 16 bit
  • Beckhoff EL4038 | EtherCAT Terminal, 8-channel analog output, voltage, ±10 V, 12 bit
  • Beckhoff EL4034 | EtherCAT Terminal, 4-channel analog output, voltage, ±10 V, 12 bit
  • Beckhoff EL4032 | EtherCAT Terminal, 2-channel analog output, voltage, ±10 V, 12 bit
  • Beckhoff EL4031 | EtherCAT Terminal, 1-channel analog output, voltage, ±10 V, 12 bit
  • Beckhoff EL4028 | EtherCAT Terminal, 8-channel analog output, current, 4…20 mA, 12 bit
  • Beckhoff EL4024 | EtherCAT Terminal, 4-channel analog output, current, 4…20 mA, 12 bit
  • Beckhoff EL4022 | EtherCAT Terminal, 2-channel analog output, current, 4…20 mA, 12 bit
  • Beckhoff EL4021 | EtherCAT Terminal, 1-channel analog output, current, 4…20 mA, 12 bit
  • Beckhoff EL4018 | EtherCAT Terminal, 8-channel analog output, current, 0…20 mA, 12 bit
  • Beckhoff EL4014 | EtherCAT Terminal, 4-channel analog output, current, 0…20 mA, 12 bit
  • Beckhoff EL4012 | EtherCAT Terminal, 2-channel analog output, current, 0…20 mA, 12 bit
  • Beckhoff EL4011 | EtherCAT Terminal, 1-channel analog output, current, 0…20 mA, 12 bit
  • Beckhoff EL4008 | EtherCAT Terminal, 8-channel analog output, voltage, 0…10 V, 12 bit
  • Beckhoff EL4004 | EtherCAT Terminal, 4-channel analog output, voltage, 0…10 V, 12 bit
  • Beckhoff EL4002 | EtherCAT Terminal, 2-channel analog output, voltage, 0…10 V, 12 bit
  • Beckhoff EL4001 | EtherCAT Terminal, 1-channel analog output, voltage, 0…10 V, 12 bit
  • Beckhoff EL4172 | EtherCAT Terminal, 2-channel analog output, multi-function
  • Beckhoff ED4174 | EtherCAT Terminal, 4-channel analog output, multi-function
  • Beckhoff ED4172 | EtherCAT Terminal, 2-channel analog output, multi-function
  • Beckhoff ED4078 | EtherCAT Terminal, 8-channel analog output, multi-function
  • Beckhoff EL4078 | EtherCAT Terminal, 8-channel analog output, multi-function
  • Beckhoff ED4074 | EtherCAT Terminal, 4-channel analog output, multi-function
  • Beckhoff EL4074 | EtherCAT Terminal, 4-channel analog output, multi-function
  • Beckhoff ED4072 | EtherCAT Terminal, 2-channel analog output, multi-function
  • Beckhoff EL4072 | EtherCAT Terminal, 2-channel analog output, multi-function
  • Beckhoff EM3712 | EtherCAT Terminal, 2-channel analog input, relative pressure
  • Beckhoff EM3701 | EtherCAT Terminal, 1-channel analog input, differential pressure
  • Beckhoff ELX3351-0090 | EtherCAT Terminal, 1-channel analog input, measuring bridge
  • Beckhoff ELX3351 | EtherCAT Terminal, 1-channel analog input, measuring bridge
  • Beckhoff ELX3314-0090 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELX3314 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELX3312-0090 | EtherCAT Terminal, 2-channel analog input, temperature
  • Beckhoff ELX3312 | EtherCAT Terminal, 2-channel analog input, temperature
  • Beckhoff ELX3252 | EtherCAT Terminal, 2-channel analog input, potentiometer
  • Beckhoff ELX3204-0090 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELX3204 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELX3202-0090 | EtherCAT Terminal, 2-channel analog input, temperature
  • Beckhoff ELX3202 | EtherCAT Terminal, 2-channel analog input, temperature
  • Beckhoff ELX3184 | EtherCAT Terminal, 4-channel analog input, current, 4…20 mA
  • Beckhoff ELX3181 | EtherCAT Terminal, 1-channel analog input, current, 4…20 mA
  • Eaton ELC-PA10AADR ELC Logic Controller, 10 I/O
  • EATON CORPORATION A200M3CX MOTOR STARTER
  • Eaton Cutler Hammer CB00002 Vacon PC00002-H Power Board CX/CXL, 30kW / 500V
  • Eaton EL1600USBDIN CPU
  • EATON MTL CP-DYNB-DI 16CH DI FTA CC Base Board,MTL16ATEXCPDYNX
  • Eaton ELC2-PV28NNDR-2 AND ELC-EX16NNDR-2 Programmable Logic Controller
  • EATON 40071361110 CEAG LP-STAR UNIT, 220-240V INPUT/OUTPUT
  • EATON CEAG CU CG-S , 40071360300 Control Unit
  • EATON EX16NNDRW4520024 Logic Controller Module 250VAC 50/60HZ 1.5AEATON EX16NNDRW4520024 Logic Controller Module 250VAC 50/60HZ 1.5A
  • EATON ELCPV28NNDR CONTROLLER 28I/O 16INPUT DC 120OUTPUT RELAY
  • EATON CORPORATION CAN-16DI/P / CAN16DIP STOCK 1276-A
  • Eaton ELC2-PV28NNDR PV Controller, 28 I/O, 16 DI, 12 RO
  • Eaton ELC-EX16NNDR Programmable Logic Controller Digital Expansion Module 16 I/O
  • EATON CORPORATION 104-1193-006 MOTOR
  • Eaton Crouse Hinds CLD Programmer /Field Unit P/N.T6527-50-03-00
  • Eaton Vickers EEA-PAM-513-A-33 Replace of EEA-PAM-513-A-32 Power Amplifier
  • EATON COOPER Crose-Hinds 9373-FB-PS-SS-040, MTL field bus barrier system 12-Spur
  • EATON DURANT 58820-400 TOTALIZER 5882-0 58820400
  • Hirschmann MM3-1FXS2/3TX1(-EEC) MICE3000 media modules
  • Hirschmann MM4-4TX/SFP MICE4000 media modules
  • Hirschmann MM3-4FLM4 MICE3000 media modules
  • Hirschmann MM20-Z6Z6Z6Z6 Open variant media modules
  • Hirschmann MM3-1FXL2/3TX1 MICE3000 media modules
  • Hirschmann MM3-2FXM2/2TX1(-EEC) MICE3000 media modules
  • Hirschmann MM3-4FXS2 MICE3000 media modules
  • Hirschmann MM3-2FXS2/2TX1 MICE3000 media modules
  • Hirschmann MM20-F4F4F4F4 Open variant media modules
  • Hirschmann MM2-2FXS2 MICE2000 media modules
  • Hirschmann MM2-2FXM2 MICE2000 media modules
  • Hirschmann MM2-4FXM3 MICE2000 media modules
  • Hirschmann MM2-2FLM4 MICE2000 media modules
  • Hirschmann MM2-4TX1(-EEC) MICE2000 media modules
  • Hirschmann MM2-2FXM3/2TX1 Media module for MICE Switches
  • Eaton PXR-PCAM IL120009EN Ethernet (Modbus TCP)
  • Eaton PXR-ECAM-MTCP IL0131132EN Ethernet (Modbus TCP)
  • Eaton MTL PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier
  • Eaton EBR-Z high impedance bus differential relay
  • Eaton EBR-3000 high impedance bus differential relay
  • Eaton EGR5000 generator relay
  • Eaton EDR-5000 Distribution Protection Relay
  • Eaton F810 Redundant fieldbus power for Foxboro I/A series™ control system
  • Eaton 5073E-T 7-Port + 3-Combo Port Gigabit Managed Ethernet Switch
  • Eaton 2080E-T 8-Port Managed Ethernet Switch
  • Eaton 1080E-T 8-Port Ethernet switch
  • Eaton 1050E-T 5-Port Basic Ethernet Switch
  • Eaton TD150048EN Power Xpert energy meter series
  • Eaton NZMH2-4-A200 NZM complete molded case circuit breaker
  • Eaton NZMH3-AE600-NA NZM complete molded case circuit breaker
  • Eaton NZMB2-AF250-NA NZM complete molded case circuit breaker
  • Eaton NZMN4-AEF600-NA NZM complete molded case circuit breaker
  • Eaton NZMH4-AE1250-S1 NZM complete molded case circuit breaker
  • Eaton NZMH4-AE1600 NZM complete molded case circuit breaker
  • Eaton NZMN2-A125-NA NZM complete molded case circuit breaker
  • Eaton NZMH4-AE1200-NA NZM complete molded case circuit breaker
  • Eaton NZMH2-VEF200-BT-NA NZM complete molded case circuit breaker
  • Eaton NZMH2-AF175-BT-NA NZM complete molded case circuit breaker
  • Eaton NZMB1-AF70-NA NZM complete molded case circuit breaker
  • Eaton NZMB2-AF70-BT-NA NZM complete molded case circuit breaker
  • Eaton NZMB2-A80-BT-NA NZM complete molded case circuit breaker
  • Eaton NZMH2-A63-NA NZM complete molded case circuit breaker
  • Eaton NZMB2-AF15-NA NZM complete molded case circuit breaker
  • Eaton NZMN2-A40-NA NZM complete molded case circuit breaker