During fired operation, heat from fuel combustion is transferred
to the furnace shell, mainly through radiation. Flue gases leaving
the furnace enter vertical uptakes where the heat is transferred
to helix tubes, mainly through convection. If the boiler is config
ured as a hybrid, the electric heater provides an alternative
heat source.
Heat transferred through the furnace shell or the helix tube walls
evaporates the adjacent saturated water on the boiler’s water
side. This causes steam bubbles to form. Because the steam
bubbles have a much lower specific density than the water, they
rise rapidly into the steam space, where the water and steam
are separated.
Control
Like other Alfa Laval equipment on board, the Aalborg OS-TCi
uses Alfa Laval Touch Control. This recognizable, user-friendly
interface features a graphical touchscreen with intuitive navi
gation, making it easy for the crew to learn and use it correctly.
Robust and PLC-based, the control system offers future-proof
expansion possibilities and support for remote troubleshooting.
Maintenance
The Aalborg OS-TCi is effectively self-cleaning thanks to its
TCi (Turbo Clean, intelligent) technology, which keeps the boiler
running efficiently and prolongs its service life. The TCI cleaning
process is fully automatic.