Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

Hitachi 500NMD01 Compact Modem

From:Hitachi | author:Mr.Chen | Time :2024-07-25 | 809 view: | Share:

- Integrated Managed Layer 2 Switch

- 24... 60 VDC supply voltage

- 4x 10/100 BaseT (RJ45. auto-negotiation)

- 1x SHDSL port for copper lines

- Redundant topology via Spanning Tree Protocol (STP/RSTP/MSTP)

- 1x RS-232/ RS-485 interface for tunneling of serial protocols

Applications

The DIN-rail mountable 500NMD01 is a managed plug-and-play Layer 2 switch that offers

- 4 Fast Ethernet auto-negotiating RJ45 ports with automatic MDI/X (automatic cross detection and correction)

- 1 2-wire SHDSL port for dedicated copper cable

- 1 RS-232/ RS-485 interface for tunneling of serial protocols

The switch provides a redundant topology via Spanning Tree Protocol (STP/ RSTP/ MSTP). It supports VLAN framing and serial data tunnelling.

Ethernet can be distributed within the station via the switch's four RJ45 ports.

The SHDSL port can be used for interstation interconnections up to a maximum distance of 25 km (0.8 mm diameter copper cable).

The SHDSL interface connects to any EDS500 SHDSL-compatible device, including the 560NMS24 and 560NMS34. as well as any EFM-based SHDSL device.

Features

For documentation purposes, the Ethernet ports are labelled 1 to 4 and there are no specific uplink ports.

All ports are functionally identical, and the SHDSL port is connected via a pluggable threaded connector.

The link and speed status of each Ethernet port and SHDSL port is indicated by status indicators (see ‘Connectors and Indicators’).

The switch learns the Ethernet address by analysing incoming frames and stores it in a lookup table (up to 2048 entries).

used to forward frames only to the correct port. If it is a broadcast or multicast, or if the destination address is not found in the lookup table, the

then the received frame is forwarded to all ports other than the receiving port. If an incoming frame with a specific source address does not refresh the entry in the lookup table, the

entry will age out in up to 304 seconds (by default, this value is configurable).

For IEEE 802.1Q VLAN frames, the switch can be configured in VLAN or transparent mode. In transparent mode, the switch does not change any frames or frame TAGs;

In VLAN mode, the switch can be configured to support multiple applications, such as trunks or access ports.

The switch can support quality of service if it uses IEEE 802.1p-compliant frame formats.

The switch can divide frames into up to four queues, which can be configured as priority-based queues or weighted fair queues.

The 500NMD01 uses a wide-range power supply that operates from 24 to 60 V. The switch can be configured to operate on a wide-range power supply.

The switch itself, the Ethernet ports, as well as the SHDSL connection, the RS-232 interface, and the Extended Bus Interface (Ext) are hot-swappable.

Topology

The 500NMD01 offers a total of five ports for use with end devices, switches, bridges, hubs and routers.

The switches can be easily constructed in star, ring, or line topologies.

Redundant topologies can be automatically detected and processed via Rapid Spanning Tree Protocol (RSTP) or Multiple Spanning Tree Protocol (MSTP).

This is fully backward compatible with the widely used Spanning Tree Protocol (STP).

Management and Configuration

Management and configuration of the 500NMD01 can be accomplished via Telnet, Secure Shell (SSH), SNMP, RS-232. or Web interface.

All methods can be used to read or write device parameters.

In addition, the interface and alarm status of the device can be monitored via IEC 60870-5-101 or -104.

Existing configurations can be saved and restored. The configuration can also be stored in an external configuration stick (500NMA01).

This makes it simple to swap devices without trained personnel.

By default, the 500NMD01 switch is configured with an IP address of 10.0.0.2. a subnet mask of 255.0.0.0. and a gateway of 10.0.0.1.

Connections for configuration purposes can be accepted over any interface. All Ethernet ports are in the administrative state by default.

The RS-232 interface is preconfigured for a baud rate of 57600. 8 data bits, no parity, and 1 stop bit (57600.8N1).

Any terminal software (e.g. HyperTerminal) can access the command line interpreter configured through this interface.

  • Kollmorgen AKT2G-AC-FAN-001 fan cartridge
  • Kollmorgen AKT-AN-820-000 8-Channel Analog Input Terminal
  • Kollmorgen 4-Channel Analog Input Terminal (AKT-AN-420-000)
  • METSO D201379 PC Board PLC & ADD-ON Board
  • Metso PDP403 Distributed Processing Unit
  • METSO D201505 / D201463 network controller
  • METSO ntel D33025 Motherboard
  • METSO ACN MR D201463 DCS Controller
  • METSO ACN MR D201505R DCS Controller
  • METSO ACN MR D201380 DCS Controller
  • METSO ACN MR D201139 DCS Controller
  • METSO ACN MR D202214 DCS Controller
  • METSO ACN MR D202275 DCS Controller
  • Metso D201376 Industrial Analog Input Module
  • Metso D201134 Process Control Module
  • Metso d200175 ver: 2.04 personality module
  • Metso D200137 ACN RT Node with D200175
  • METSO ACN CS CONTROLLER D201925 VER 2.15
  • METSO D100644 Electrical Automation Module
  • Kollmorgen CB06560 PRD-B040SAIB-62 Control Module
  • Servostar 310 Kollmorgen Servo Amplifier
  • Kollmorgen S20330-SRS Digital AC Servo Drives
  • Kollmorgen S22460-SRS Digital AC Servo Drives
  • Kollmorgen S70602-NANANA S700 Servo Driver
  • BJRL-20012-110001 Kollmorgen Goldline Smart Drives
  • Kollmorgen SAM-DA-400-07B-P4N-F SAM Servo Amplifiers
  • Kollmorgen CP320260 Servo Drive
  • Kollmorgen S72402-NANANA - AC servo drives
  • Kollmorgen E33NRHA-LNN-NS-00 Precision Motion Control Module
  • Kollmorgen S20360-SRS Servo Drive
  • Kollmorgen E33NCHA-LNN-NS-00 Precision Motion Control Module
  • Kollmorgen CR06200-000000 Servo Drive
  • Kollmorgen DIGIFAS7201 Digital Industrial Servo
  • CB06251 Kollmorgen Servo Drive
  • Kongsberg TRX32 FILTER (303067B) | Elektro Marine
  • Kongsberg MRU-M-MB3 | Motion Reference Unit
  • Kongsberg TRX32 303088 | eight-channel I/O module
  • Kongsberg MRU2 Motion Reference Unit
  • KONGSBERG MRU-M-SU1 Industrial Measurement Unit
  • Kongsberg RMP201-8 Versatile Remote Input/output System
  • Kongsberg dPSC 8100183 Dual Process Segment Controller
  • YOKOGAWA YS1700-100/A06/A31 Programmable indicating controller
  • YOKOGAWA YS1700-100/A06/A31 Programmable Indicating Controller
  • KS9-5*A | Yokogawa | MXL DSC Cabl
  • KS8-5*A | Yokogawa | MXL DSC Cabl
  • KS2-05*A | Yokogawa | MXL DSC Cabl
  • YOKOGAWA PW482-10 S2 Power Supply Module
  • Yokogawa SCP451-11 S1 Processor Module
  • YOKOGAWA SR1030B62 High-Frequency Module
  • Yokogawa CP451-50 S2 Processor Module
  • YOKOGAWA AAI143-H50 Analog I/O Modules
  • YOKOGAWA AMM42 2-Wire Transmitter Input Multiplexer Module
  • SDV144-S63 | Yokogawa | Digital Input Module
  • Yokogawa AIP830-111 Operation Keyboard for Single loop Operation
  • Yokogawa S9361DH00 Control Module / Terminal Board
  • Yokogawa ATK4A-00/S1 KS Cable Interface Adapter
  • YOKOGAWA PW701 Power Supply Module
  • YOKOGAWA Dual-Redundant V-Network Router AVR10D-A22010
  • YOKOGAWA PW441-10 Communication Module
  • YOKOGAWA VI451-10 S2 Communication Module
  • Yokogawa VC401-10 Coupler Modules
  • Yokogawa ALP121 PROFIBUS-DP Communication Module
  • Yokogawa NFAI841-S00/A4S00 Analog Input/Output Module
  • YOKOGAWA AIP591 Transceiver Control Module
  • YOKOGAWA AIP578 Transceiver Control Module
  • YOKOGAWA PW501 Power Supply Unit Brand
  • Yokogawa YNT511D-V42 Bus Repeater Module
  • YOKOGAWA AIP171 Transceiver Control Module
  • YOKOGAWA VI702 Vnet/IP Interface Card
  • 2302-32-VLE-2 YOKOGAWA Data Acquisition Module
  • Yokogawa ATK4A-00 16-Channel KS Cable Interface Adapter
  • YOKOGAWA ALR121-S00 Serial Communication Module
  • CP461-50 | Yokogawa | Processor Module
  • Yokogawa AIP121-S00 Control Module
  • YOKOGAWA UR1800 Wireless Communication Module
  • Yokogawa| LC82 *A Redundant RL-Bus Interface Card
  • YOKOGAWA ST6 Industrial Control Module
  • YOKOGAWA ANR10D ER Bus Node Unit
  • YOKOGAWA SDV144-S13 S1 Digital Input Module
  • YOKOGAWA NFAI143-H00 analog I/O module
  • YOKOGAWA EB501 Bus Interface Module
  • Yokogawa CP451-10-S2 High-Performance Processor Module
  • YOKOGAWA V0/E1/TCAM/L08 High-Precision Temperature Controller
  • YOKOGAWA VO/E2/TCDM24/L8 High-Precision Temperature Controller
  • YOKOGAWA 16137-119 Process Control Module
  • YOKOGAWA 16114-500 I/O Module for Process Control Systems
  • Yokogawa PSCDM024DCBAN - Critical Discrete Module
  • YOKOGAWA 16137-151 Digital Input Module
  • YOKOGAWA 16137-188 Digital Input Module
  • YOKOGAWA 16137-222 Digital Input Module
  • YOKOGAWA 16137-223 Digital Input Module
  • YOKOGAWA 16137-153 Digital Input Module
  • Watlow SUB21/IV10 0-10 V input adaptor
  • Watlow ITOOLS/NONE/USB U SB configuration kit
  • Watlow CTR500000/000 100 A Current transformer
  • Watlow CTR400000/000 50 A Current transformer
  • Watlow CTR200000/000 25 A Current transformer
  • Watlow CTR100000/000 10 A Current transformer
  • Watlow SUB35/ACCESS/249R.1 2.49R Precision resistor
  • Vibro-meter vmf-RLC16-V111 200-570-101-015 200-570-000-111 Relay Card
  • Vibro-meter vmf-IOC4T 200560-101-017 200-560-000-111 I/O module
  • vmf cpum vmf-cmc16 200-530-111-013 200-530-100-014 Vibro-meter Monitoring system Modulee
  • Vibro-meter 200-595-045-114 | CPUM | Vibration Processor Module
  • Vibro-meter SIM-275A 200-582-500-013 state-of-the-art protection and monitoring module
  • Vibro-meter VM600 RLC16 200-570-000-111 200-570-101-015 Relay Card
  • Vibro-meter VM600 RPS6U 200-582-600-013 cutting-edge monitoring module
  • Vibro-meter VM600 CMC16 200-530-025-014 200-530-111-013 input/output card
  • Vibro-meter 200-570-000-014 200-570-101-013 VM600 Protection Module
  • Vibro-meter 620-002-000-113 620-003-111-112 VM600 XIO16T input/output card
  • Vibro-meter 600-003 620-001-001-116 VM600 XMV16 input/output card
  • Vibro-Meter 444-680-000-511 Level Detector & Proximity Sensor
  • Vibro-meter VM600 MPC4 200-510-111-034 200-510-070-113 Module
  • Vibro-Meter IOCN 200-566-000-113 | I/O Communication Node
  • Vibro-meter VM600 IOC16T 200-565-000-013 / 200-565-101-013 Industrial Control Module
  • Vibro-Meter 200-566-000-012 VM600 IOCN Communication board
  • Vibro-meter 200-560-000-113 VM600 power supplies Module
  • VIBRO 573-935-202C - High-Accuracy Interface Module
  • Vibro-meter 200-595-002-011 Modular Safety Relays
  • 200-560-000-016 VIBRO I/O Module
  • YOKOGAWA 8662570000 Terminal Module
  • YOKOGAWA 8596020000 Terminal Module
  • YOKOGAWA 8662560000 Terminal Module
  • YOKOGAWA PSCAMAAN | Process Control Analog Input Module
  • YOKOGAWA DR1030B60 High-Precision Pressure Transmitter
  • Yokogawa adv551 Digital I/O Modules
  • Yokogawa aai543 Analog I/O Modules (for FIO)
  • YOKOGAWA LR 4220E Level Controller Module
  • Yokogawa SR1008B62 Signal Relay Module