◼ Reduce business risks by minimizing process downtime
◼ Save on installation costs
◼ Preserve HART® signals
Introduction
If concerns about downtime and wiring costs are preventing
you from migrating your Foxboro™ I/A Series 100 I/O to a new
DeltaV™ system, consider DeltaV Flex.Connect solutions for
Foxboro I/A Series 100 I/O.

Benefits
Reduce business risks by minimizing process downtime. This
solution brings device signals to DeltaV I/O from existing Foxboro
I/A Series 100 Fieldbus Modules (FBMs). Keeping device
wires intact accelerates the new system startup, enabling you to
rapidly resume production.
Save installation costs. Eliminating new device wiring saves money
and reduces the risk of errors. Time and material savings are
significant.
Preserve HART signals. Use HART® Pass-through for complete
diagnostics at the DeltaV workstations.
Product Description and Specification
DeltaV Flex.Connect solutions provide direct connection from
Foxboro I/A Series 100 I/O to DeltaV Electronic Marshalling.
The following Foxboro I/A Series 100 I/O FBM point types have
DeltaV Flex.Connect solutions as described below:
Series 100
DeltaV Flex.Connect solutions passive nosecone adapters and
cables connect FBM terminal blocks to standard DeltaV AI, AO,
DI, and DO CHARM terminal blocks via a passive DIN-rail mount
nosecone adapter (see Figure 1).
◼ Analog Inputs FBM01
8 Analog Inputs connect to 8 4-20mA AI HART CHARMs
◼ Analog Inputs/Outputs FBM04
4 Analog Inputs and 4 Analog Outputs connect to 4, 4-20mA
DeltaV AI HART & 4, 4-20mA DeltaV AO HART CHARMs
◼ Digital Inputs FBM07A/12A
16 Digital Inputs connect to 16, 24 VDC DeltaV DI 24 VDC Isolated
CHARMs
◼ Digital Inputs FBM07B/12B
16 Digital Inputs connect to 16 24VDC Low-Side Sense (dry
contact) CHARMs
◼ Digital Inputs FBM08/13
16 Digital Inputs connect to 16 120 VAC Isolated CHARMs
◼ Digital Inputs/Outputs FBM09A
8 Digital Inputs (external power source) connect to 8 24VDC
Isolated CHARMs and 8 Digital Outputs connect to 8 24VDC
Isolated CHARMs
◼ Digital Inputs/Outputs FBM09B
8 Digital Inputs (internal power source) connect to 8 24VDC
Isolated CHARMs and 8 Digital Outputs connect to 8 24VDC
Isolated CHARMs
◼ Digital Inputs FBM09C
8 Digital Inputs (external power source) connect to 8 24VDC
Low-Side Sense (dry contact) CHARMs and 8 Digital Outputs
connect to 8, 24VDC Isolated CHARMs
◼ Digital Inputs FBM09D
8 Digital Inputs (internal power source) connect to 8 24VDC
Isolated CHARMs and 8 Digital Outputs connect to 8 24VDC
Isolated CHARMs
◼ Digital Inputs FBM10/15
8 Digital Inputs connect to 8 120VAC Isolated CHARMs and 8
Digital Outputs connect to 8 120VAC High Side CHARMs
Ordering Information (Cont’d)
Cables are available in lengths required for your migration
project. These cables can be pre-wired and tested to DeltaV I/O
terminal blocks. These custom loomed cables are all connected
to the nosecone adapter on one end, open-end / flying lead on
the other end, all open wires marked with the corresponding
pin number and have ferrules on each wire, 18-22 AWG can be
specified, and flying-lead to connect to the DeltaV I/O. Contact
your local Emerson representative for pricing and availability.
Prerequisites
A preliminary site visit is required to survey installed control
system architecture and electrical grounding practices, to
document I/O models and numbers of each, and to review
schedule constraints and turnaround objectives. Qualified
Emerson engineers or technicians perform site reviews.
Services
For help in planning, justifying, or implementing your system
migration, contact your local Emerson representative. Expert
consultants are available to advise you on a variety of concerns,
including safety system design, implementation and standards
compliance, digital buses, wireless applications, control performance,
and process optimization.