Product Description

Electronic Marshalling for Migrations hardware includes:

• CHARM I/O Carrier (DIN-rail mounted and supports

redundant pair of CHARM I/O Cards).

• CHARM I/O Card (CIOC) provides communication between

CHARMs and the Ethernet I/O network to M-series, S-series,

and PK controllers. The CIOC has Achilles Communications

Certification Level 1 and the redesigned CIOC2 has more

computing power and Achilles Communications Certification

Level 2. The CIOC2 is a drop-in replacement for the CIOC.

• CHARM Baseplate (DIN-rail mounted with interleaving power

and bus connectors. Supports 12 CHARMs and their terminal

blocks, as well as connection for injected field power).

• CHARM Terminal Block (removable terminal block

providing terminal connections to field wiring and

physical latch for CHARM).

• CHARMs (Characterization Module for each field signal.

Provides basic analog to digital conversion, connectivity

to redundant communication bus, and fault isolation).

• Cable Extenders that provide flexibility in carrier mounting.

• Baseplate terminators (provides bus terminations for

redundant I/O bus).

• 19” Migration Panels (provides DIN-rail mounting for two

migration CIOC’s or two baseplates and cable extenders

for installation into your standard 19” legacy cabinets).

The CHARM I/O card carrier is supposed to be mounted

on a vertical DIN-rail and can communicate with up to

eight CHARM Baseplates mounted vertically or on migration

panels and connected to each other through extender cables.

The bus terminators are attached to the last baseplate.

Each CHARMs Migration Baseplate Assembly is

ordered pre-loaded with 24 terminal blocks that are

ready to receive field wires from 2-, 3- , and 4-wire devices.

Electronic Marshalling eliminates the need to scramble the

field wiring or to partition the I/O to match signals to channel

types of specific cards. Simply connect field signals in an orderly

fashion as desired. Insert the appropriate CHARM into each

terminal block to complete the field circuit and the signal

is ready to be used by any, up to four controllers.

For each Migration CIOC installation you will need to

determine the quantity and connector cable length as

well as the appropriate quantity of top and/or bottom

baseplate terminators.

The Migration CIOC assembly has a height of 6 EIA units

(10.5 inches) and is designed to be mounted at the top

of the migration cabinet and connected to the CHARM

baseplate assemblies through the cables and cable extenders.

It should be noted that the CIOC can be mounted on vertical

DIN-rail anywhere in the cabinet (front, back, side, top,

middle, bottom) and connected to the CHARM baseplate

assembly the same way. NOTE: the CIOC cannot be mounted

on a horizontal DIN-rail.

The Migration CHARM baseplate assembly has a height of

3 EIA units (5.25 inches) which allows for each installation

to determine the mounting location within each cabinet.

The user can decide to reuse existing wire way / cable tray,

mount each assembly adjacent to each other, or mount with

spacing between each assembly. DeltaV CHARMs allow for

installation flexibility by allowing each assembly to be mounted

as needed to achieve the best result for each customer-specific

termination installation.

Each CHARM acts as a circuit protection device and field wiring

disconnects. Signals are current limited or fused to protect

against wiring faults to ground. Each CHARM provides surge

protection to meet industry standards in the area of EMC, and is

designed to fail during overvoltage conditions due to incorrect

field wiring. Signal faults are isolated to the single CHARM.

CHARMs can be partially ejected to a locked position that

disconnects the field wiring from the system to perform field

maintenance actions or to remove power to a field device.

Activating the CHARM latch ejects the CHARM to the detent

position. Closing the latch locks the CHARM in place and

isolates the field wiring for field work.

The CIOC communicates over Ethernet with up to four

controllers, allowing great flexibility and ease of system

expansion. Additional controllers can be added to

accommodate increased control scope and I/O can be

  • ENOTEC GAS ANALYZER SYSTEM OXITEC 5000 SME-53310000
  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch
  • Eaton 5884-1400 6-Digit Dual Preset Control W/ Batch Control
  • Eaton 1023843 Power Circuit Board 94V
  • EATON ES4P-221-DRXD1 24VDC NSMP
  • Eaton DH222NWK heavy duty fusible safety switch
  • Eaton Touch Panel 10.1 inch XV-303-10-C00-A00-1C
  • Eaton RDF200J-3 Bussmann series RDF fused rotary disconnect switch
  • EATON CORPORATION A200M2CACD A200 NEMA Motor Control
  • Eaton SPD160208Y3J Surge Protection Device
  • EATON CORPORATION SPD160208Y3K SURGE SUPPRESSOR
  • EATON DILM400/22 (RA250) 200KW Coil Voltage/Coil 110-250V 40-60Hz/DC
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • EATON CORPORATION D820MPM HMI
  • EATON PXG900 Power Xpert Insight Gateway 900
  • Eaton Durant 5882-7 Digital Counter loc2D3
  • EATON AXCELIS 1220-0012-0002 DISK VACUUM DI CONTROLLER
  • Eaton 1383B-6501 80 Series Photoelectric Sensor Head
  • Eaton FDC2100L Series C molded case switch
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • Eaton FD3200L circuit breaker
  • Eaton Touch Screen Control Panel X-152-D6-10TVRC-10
  • EATON VICKERS EEA-PAM-523-A-32 02-326001 POWER AMPLIFIER
  • Saacke Seavis HMI 03 EATON XV-102-B6-35TQR-1AL-PLC HMI Touch Panel
  • EATON MTL E05016 DIGITAL INPUT EUROCARD E05516-2134
  • Eaton HFD3150 3P 150A 600VAC Circuit Breaker
  • Eaton HMIVU06CUNB1 HMi Operator Interface, RS-232, 5.6"
  • Cutler-Hammer/ Eaton Panelmate PowerPro 5785 with cables LCD monitor
  • Eaton D100CA40 40 I/O Micro PLC 115VAC Input Triac Output
  • EATON CUTLER HAMMER 66D2032GX1 MP-3000 PROTECTION RELAY
  • EATON R9L3200FJ Rotary Disconnect Switch
  • EATON CORPORATION E51CLT16PCU Switch
  • Aerotech Modular System Control Console
  • Aerotech TV Series Transformers
  • Aerotech TM5 Transformer Module (500 watts)
  • Aerotech TM3 Transformer Module
  • Aerotech UFM Noise Filter Module
  • Aerotech MFM10-2 Motor filter module
  • Aerotech MFM10-1 Motor filter module
  • Aerotech MPG Handwheel Pendant
  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3246-0000 | EtherCAT Terminal, 6-channel analog input, temperature
  • Beckhoff ELM3244-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3148-0000 | EtherCAT Terminal, 8-channel analog input, multi-function
  • Beckhoff ELM3146-0000 | EtherCAT Terminal, 6-channel analog input, multi-function
  • Beckhoff ELM3144-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckwith Electric M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-3919A Graphic Display Unit/ Human Machine Interface
  • Beckwith Electric M-4172 Digital Motor Bus Transfer System
  • Beckwith Electric M-3904B Remote Monitoring Module
  • Beckwith Electric M-3410A Intertie/Generator Protection Relay
  • Beckwith Electric B-1612 Adapter
  • Beckwith Electric B-1652 Adapter
  • Beckwith Electric B-1685 Adapter
  • Beckwith Electric M-2035 Analog to Digital Interface Module
  • Beckwith Electric B-2291 Digital Input Guard
  • Beckwith Electric M-2406 Recloser Control Adapter Chassis
  • Beckwith Electric M-3908 Universal Contact Input Adapter
  • Beckwith Electric M-3801D IPS Plot Software
  • Beckwith Electric M-7651A D-PAC
  • Beckwith Electric M-2979 Recloser Control Cabinet
  • Beckwith Electric M-0359 SYNCROCLOSER MOD512
  • Beckwith Electric M-2001C-6ELFA Tap Changer Controller Voltage Regulator Control
  • Beckwith Electric M-0124 TERMINAL BOARD ADAPTER PLATE 13 POS
  • Beckwith Pride M-0296C 3ph Programmable Relay
  • Beckwith Electric M-0388 Syncrocloser Check Relay
  • M-0170A AC Current Relay Beckwith Electric
  • Beckwith Electric Intertie Protection M-3520 Instruction Manual
  • M-3311 M-3311 7113 BECKWITH ELECTRIC TRANSFORMER PROTECTION RELAY
  • Pride M-0296b 3 phase Programmable Relay Beckwith Electric Co
  • Beckwith Electric M3310 Integrated Transformer Protection Panel
  • Beckwith M-0145 First Customer Protector
  • Beckwith Electric M-0296C 3 phase Programmabel Relay
  • Beckwith Electric M-0389 VOLTAGE VERIFIER
  • M-3425 M-3425-A1DE BECKWITH ELECTRIC GENERATOR PROTECTION RELAY SL
  • Beckwith Electric M-0420 Multifunction Relay Protection Module 48VDC
  • M-3430 M-3430M0D515 BECKWITH ELECTRIC GENERATOR PROTECTION RELAY
  • Beckwith Electric Tapchanger Control M-0067E
  • Beckwith M-2001D-6L4S20C0S0X Tap Changer Control Surplus
  • BECKWITH ELECTRIC M3425A-STD1 Generator Protection 85-280VDC
  • Beckwith Electric High Speed Sync-Check Relay #M-0245C Mod #22 (NIB)
  • Beckwith Electric M-7679 R-PAC