Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

Euresys Coaxlink QSFP+ Four-connection CoaXPress-over-Fiber frame grabber

From:Euresys | author:Mr.Chen | Time :2024-10-31 | 553 view: | Share:

At a Glance

• One QSFP+ port compliant with 40 Gbps optical modules

• 5.000 MB/s camera bandwidth

• PCIe 3.0 (Gen 3) x8 bus: 6.700 MB/s bus bandwidth

• Feature-rich set of 20 digital I/O lines

• Extensive camera control functions

• Memento Event Logging Tool

• Compatible with CustomLogic: Your own FPGA logic

Benefits

What is CoaXPress-over-Fiber?

CoaXPress-over-Fiber is a light but significant extension of the existing CoaXPress specification to support transport over fiber optics.

CoaXPress (CXP) is the de-facto standard for high-bandwidth computer vision applications. CoaXPress 2.1. 

the latest version of the specification, specifies the CXP-12 speed, a 12.5 Gbps (Gigabit per second) connection over a coaxial copper cable. 

As link aggregation is common with CoaXPress, bandwidths of 50 Gbps (12.5 x 4) are easily achievable with four CXP-12 connections. 

CoaXPress-over-Fiber has been designed as an add-on to the CoaXPress specification. 

It provides a way to run the CoaXPress protocol, as it is, unmodified, over a standard Ethernet connection, including fiber optics. 

As such, CoaXPress-over-Fiber uses standard electronics, connectors and cables designed for Ethernet, but the protocol is CoaXPress, not Ethernet, not GigE Vision.

Read more about CoaXPress-over-Fiber on our technology page.

PCIe 3.0 (Gen 3) x8 bus

• 7.800 MB/s peak bus bandwidth

• 6.700 MB/s sustained bus bandwidth

Acquire images from the fastest and highest resolution cameras

• Highest data acquisition rate in the industry

• Up to 5.000 MB/s bandwidth from camera to host PC memory

What are the pros and cons of using fiber optics?

Pros

• First and foremost, cable length is not an issue anymore as fiber connectivity is basically not limited in length.

• Fiber optics provide more bandwidth, as connectivity at 10 and 25 Gbps per fiber is standard today and widely used in data centers.

• Fiber optics are immune to electrical noise, which will be a significant advantage on the production floor and in some medical applications.

• Fiber optics are lighter and smaller in size than the equivalent copper cabling, 

making it appropriate for applications where this characteristic is essential, like in aircrafts or vehicles.

Cons

There is no "power over fiber". As signals in fiber optics are transmitted using light, 

there is no way to transfer power over fiber optics and devices such as cameras must be powered separately.

What are the cable options for CoaXPress-over-Fiber?

One of the most important benefits of CoaXPress-over-Fiber is the wide variety of connectivity options already available from multiple companies. 

The initial connectivity options for CoaXPress-over-Fiber and the Coaxlink QSFP+ at 10 Gbps are SFP+ and QSFP+ (Quad, or four times SFP+) modules.

The advantage of using modules compared to fixed interfaces is that ports can be equipped with any suitable type of transceiver as required by the application.

A variety of transmitter and receiver types is available, allowing users to select the appropriate transceiver to provide the required optical reach over multi-mode or single-mode fiber.

What are the benefits of using CoaXPress-over-Fiber for my application?

• Available as CXP to nGMII (device) or nGMII to CXP (host) Bridge IP Cores

• Ultra-high data/frame rates

• Many accessory and cabling options to cover any length requirement

• Low CPU overhead, low latency, low jitter image acquisition

• Highest camera count per PC performance

• Very competitive cost/performance ratio

• Wide industry acceptance due to JIIA standardization

• Ready for CXP25

What are the jitter and latency of CoaXPress-over-Fiber? How do they compare to "traditional"

CoaXPress?

CoaXPress-over-Fiber is based on the CoaXPress protocol and it exhibits the same high performance as CoaXPress in terms of jitter and latency. 

In addition, as CoaXPress-over-Fiber supports higher transmission speed compared to CoaXPress, the jitter and latency will be further improved in these versions.

What is the maximum cable length with multi-mode fibers?

With a standard 40GBASE-SR4 QSFP+ Optical Transceiver Module and an MTP/MPO multi-mode fiber cable, the maximum cable length is 150 meters. 

  • YOKOGAWA YS1700-100/A06/A31 Programmable indicating controller
  • YOKOGAWA YS1700-100/A06/A31 Programmable Indicating Controller
  • KS9-5*A | Yokogawa | MXL DSC Cabl
  • KS8-5*A | Yokogawa | MXL DSC Cabl
  • KS2-05*A | Yokogawa | MXL DSC Cabl
  • YOKOGAWA PW482-10 S2 Power Supply Module
  • Yokogawa SCP451-11 S1 Processor Module
  • YOKOGAWA SR1030B62 High-Frequency Module
  • Yokogawa CP451-50 S2 Processor Module
  • YOKOGAWA AAI143-H50 Analog I/O Modules
  • YOKOGAWA AMM42 2-Wire Transmitter Input Multiplexer Module
  • SDV144-S63 | Yokogawa | Digital Input Module
  • Yokogawa AIP830-111 Operation Keyboard for Single loop Operation
  • Yokogawa S9361DH00 Control Module / Terminal Board
  • Yokogawa ATK4A-00/S1 KS Cable Interface Adapter
  • YOKOGAWA PW701 Power Supply Module
  • YOKOGAWA Dual-Redundant V-Network Router AVR10D-A22010
  • YOKOGAWA PW441-10 Communication Module
  • YOKOGAWA VI451-10 S2 Communication Module
  • Yokogawa VC401-10 Coupler Modules
  • Yokogawa ALP121 PROFIBUS-DP Communication Module
  • Yokogawa NFAI841-S00/A4S00 Analog Input/Output Module
  • YOKOGAWA AIP591 Transceiver Control Module
  • YOKOGAWA AIP578 Transceiver Control Module
  • YOKOGAWA PW501 Power Supply Unit Brand
  • Yokogawa YNT511D-V42 Bus Repeater Module
  • YOKOGAWA AIP171 Transceiver Control Module
  • YOKOGAWA VI702 Vnet/IP Interface Card
  • 2302-32-VLE-2 YOKOGAWA Data Acquisition Module
  • Yokogawa ATK4A-00 16-Channel KS Cable Interface Adapter
  • YOKOGAWA ALR121-S00 Serial Communication Module
  • CP461-50 | Yokogawa | Processor Module
  • Yokogawa AIP121-S00 Control Module
  • YOKOGAWA UR1800 Wireless Communication Module
  • Yokogawa| LC82 *A Redundant RL-Bus Interface Card
  • YOKOGAWA ST6 Industrial Control Module
  • YOKOGAWA ANR10D ER Bus Node Unit
  • YOKOGAWA SDV144-S13 S1 Digital Input Module
  • YOKOGAWA NFAI143-H00 analog I/O module
  • YOKOGAWA EB501 Bus Interface Module
  • Yokogawa CP451-10-S2 High-Performance Processor Module
  • YOKOGAWA V0/E1/TCAM/L08 High-Precision Temperature Controller
  • YOKOGAWA VO/E2/TCDM24/L8 High-Precision Temperature Controller
  • YOKOGAWA 16137-119 Process Control Module
  • YOKOGAWA 16114-500 I/O Module for Process Control Systems
  • Yokogawa PSCDM024DCBAN - Critical Discrete Module
  • YOKOGAWA 16137-151 Digital Input Module
  • YOKOGAWA 16137-188 Digital Input Module
  • YOKOGAWA 16137-222 Digital Input Module
  • YOKOGAWA 16137-223 Digital Input Module
  • YOKOGAWA 16137-153 Digital Input Module
  • Watlow SUB21/IV10 0-10 V input adaptor
  • Watlow ITOOLS/NONE/USB U SB configuration kit
  • Watlow CTR500000/000 100 A Current transformer
  • Watlow CTR400000/000 50 A Current transformer
  • Watlow CTR200000/000 25 A Current transformer
  • Watlow CTR100000/000 10 A Current transformer
  • Watlow SUB35/ACCESS/249R.1 2.49R Precision resistor
  • Vibro-meter vmf-RLC16-V111 200-570-101-015 200-570-000-111 Relay Card
  • Vibro-meter vmf-IOC4T 200560-101-017 200-560-000-111 I/O module
  • vmf cpum vmf-cmc16 200-530-111-013 200-530-100-014 Vibro-meter Monitoring system Modulee
  • Vibro-meter 200-595-045-114 | CPUM | Vibration Processor Module
  • Vibro-meter SIM-275A 200-582-500-013 state-of-the-art protection and monitoring module
  • Vibro-meter VM600 RLC16 200-570-000-111 200-570-101-015 Relay Card
  • Vibro-meter VM600 RPS6U 200-582-600-013 cutting-edge monitoring module
  • Vibro-meter VM600 CMC16 200-530-025-014 200-530-111-013 input/output card
  • Vibro-meter 200-570-000-014 200-570-101-013 VM600 Protection Module
  • Vibro-meter 620-002-000-113 620-003-111-112 VM600 XIO16T input/output card
  • Vibro-meter 600-003 620-001-001-116 VM600 XMV16 input/output card
  • Vibro-Meter 444-680-000-511 Level Detector & Proximity Sensor
  • Vibro-meter VM600 MPC4 200-510-111-034 200-510-070-113 Module
  • Vibro-Meter IOCN 200-566-000-113 | I/O Communication Node
  • Vibro-meter VM600 IOC16T 200-565-000-013 / 200-565-101-013 Industrial Control Module
  • Vibro-Meter 200-566-000-012 VM600 IOCN Communication board
  • Vibro-meter 200-560-000-113 VM600 power supplies Module
  • VIBRO 573-935-202C - High-Accuracy Interface Module
  • Vibro-meter 200-595-002-011 Modular Safety Relays
  • 200-560-000-016 VIBRO I/O Module
  • YOKOGAWA 8662570000 Terminal Module
  • YOKOGAWA 8596020000 Terminal Module
  • YOKOGAWA 8662560000 Terminal Module
  • YOKOGAWA PSCAMAAN | Process Control Analog Input Module
  • YOKOGAWA DR1030B60 High-Precision Pressure Transmitter
  • Yokogawa adv551 Digital I/O Modules
  • Yokogawa aai543 Analog I/O Modules (for FIO)
  • YOKOGAWA LR 4220E Level Controller Module
  • Yokogawa SR1008B62 Signal Relay Module
  • SC200S | Yokogawa Electric Corporation
  • Yokogawa PW301 Power Supply
  • YOKOGAWA NP53*C - Precision Control Module
  • Yokogawa F3YD64-1A Basic Input/Output Modules
  • Yokogawa F3XD64-3N Basic Input/Output Modules
  • Yokogawa F3WD64-3N Input/Output Module
  • Yokogawa F3SP21-0N CPU Module
  • YOKOGAWA F3PU10-0N Power Supply Module
  • YOKOGAWA F3PU06-0N Power Supply Module
  • YOKOGAWA F3NC02-0N Positioning Module
  • YOKOGAWA F3NC01-0N Positioning Module
  • YOKOGAWA PLC F3LC21-1N MULTI-LINK MODULE
  • YOKOGAWA F3BU06-0N Base Module
  • Honeywell DC-TFB412 51307618-176 Control Module
  • Honeywell DC-TCF901 51307593-176 9-Port Control Firewall Module
  • Honeywell DC-TCF901 cutting-edge control module
  • Honeywell DC-TFB412 Circuit Board
  • LVCDJW00000750A Watlow (Temperature Limit Controller)
  • Watlow 84700-0003 Dust cover
  • Watlow 847290006 USB type A panel mount with 2 m cord
  • Watlow RJF 21N SCC RJ45 receptacle with self closing cap
  • Watlow USBBF 21N SCC USB - B receptacle with self closing cap
  • Watlow USBF 21N SCC USB - A receptacle with self closing cap
  • Watlow 0600-0097-0000 Mixed I/O Flex Modules Quick Start Guide
  • Watlow 0600-0096-0000 High Density Flex Modules Quick Start Guide
  • Watlow 0600-0095-0000 Communications Flex Modules Quick Start Guide
  • Watlow 0600-0094-0000 F4T Controller Quick Start Guide
  • Watlow 0600-0093-0000 Setup and Operations User Guide
  • Watlow 0600-0092-0000 Installation and Troubleshooting User Guide
  • Watlow 0822-0769-0000 Module slot plug (for vacant F4T slots without flex modules
  • Watlow 0830-0858-0000 Replacement battery
  • Watlow 0830-0808-0002 (CAPUSB-A) Rubber plug USB host
  • Watlow 0830-0808-0001 (CAPUSB-MB5) Rubber plug USB mini
  • Watlow 0601-0001-0000 Controller support tools (DVD)
  • Watlow 0804-0147-0000 RC supression - Quencharc®
  • Watlow 16-0246 Current transformer
  • HIMA K9212 Safety Relay Output Module
  • Watlow 0238-1245-BLUE Accent bar (brushed aluminum blue)
  • 804B-1600-0000 Watlow (1/4 DIN Digital Temperature Controller)
  • EM00-GATE-0000 Computer Accessory by WATLOW
  • DC10-60F0-0000 SCR Power Control by WATLOW