Introduction
The BE1-11d DC Power Protection System provides flexible, reliable, and economical dc power
protection, control, monitoring, and measurement functions. The capabilities of the BE1-11d make it well
suited to provide comprehensive dc power protection. The BE1-11d offers dc overcurrent,
over/undervoltage, rate of rise, power, and thermal overload protection functions as well as breaker
reclosing and RTD (Resistance Temperature Detector) inputs with remote module. It offers breaker and
trip-circuit monitoring, and oscillography and sequential events recording. Control features include virtual
selector switches, circuit breaker control, virtual lockout, and variable-mode timers. System metering and
status information are available at the BE1-11d front panel and through the BE1-11d communication
ports. The system is suitable for mounting in OEM cubicle or retrofit switchgear applications.
A front-panel USB port or optional rear Ethernet port enables local communication between the BE1-11d
and a PC operating with BESTCOMSPlus® software. BESTCOMSPlus software simplifies the
commissioning process by providing a graphical interface for setting the BE1-11d and configuring a
protection and control scheme for your application. Through BESTCOMSPlus, all BE1-11d settings and
logic can be retained in a file for printing or uploading to other BE1-11d protection systems. Oscillography
and sequential events records can be retrieved from a BE1-11d, viewed, and printed.
Front-panel features include a large, backlit alphanumeric display and LED indicators that display system
parameters, BE1-11d settings, and BE1-11d status. Pushbuttons enable navigation through the display
menu, changes to settings, resetting of targets (with password access), and direct access to virtual
switches.
Applications
The capabilities of the BE1-11d make it ideally suited for applications with the following attributes:
• Isolation between the IT-D and the BE1-11d via fiber optic communications
• The flexibility provided by wide setting ranges, multiple setting groups, and multiple coordination
curves in one unit
• The economy provided by a multifunction unit. This one unit can provide all of the protection,
control, metering, and local and remote indication functions required for typical applications.
• The small size and limited behind-panel projection facilitates modernizing protection and control
systems in existing equipment
• Coordinated protection with other BE1-11 protection systems on both ac and dc sides of a
rectifier
• High-speed Ethernet communications and protocol support
• The capabilities of a numeric multifunction relay
• IEC 61850 functionality
Features
The BE1-11d protection system includes many features for the protection, monitoring, and control of dc
switchgear. These features include protection and control functions, metering functions, and reporting and
alarm functions. A highly flexible programmable logic system called BESTlogic™Plus allows the user to
apply the available functions with complete flexibility and customize the system to meet the requirements
of the protected dc switchgear. Programmable I/O, extensive communication features, and an advanced
user interface provide easy access to the features provided.
The following information summarizes the capabilities of this multifunction device. Each feature, along
with its setup and use, is described in detail in the later chapters of this manual.
General Features
HMI (Human-Machine Interface)
Each BE1-11d has a front-panel display and 12 LED indicators: Power Supply Status, Relay Trouble
Alarm, Minor Alarm, Major Alarm, Trip, and Indicator 1 through 7 (programmable in BESTlogicPlus). The
backlit, liquid crystal display (LCD) allows the BE1-11d to replace local indication and control functions
such as panel metering, alarm annunciation, and control switches. Four scrolling pushbuttons enable
navigation through the LCD menu tree. Parameters are changed using the Edit pushbutton. Targets,
alarms, and other registers are cleared with the Reset pushbutton. In Edit mode, the scrolling
pushbuttons provide data entry selections. Edit mode is indicated by an LED on the Edit pushbutton.
Select Control Switch and Operate Control Switch pushbuttons provide a means to control the logic
switches.
The LCD has automatic priority logic to govern which metering values are displayed on the screen so that
when an operator approaches, the metering data of most interest is automatically displayed without
having to navigate the menu structure. Scrollable metering parameters are selected on the General
Settings, Front Panel HMI settings screen in BESTCOMSPlus.
Device Information
The version of the embedded software (firmware), serial number, and style number are available from the
front panel or the communication ports.
Three free-form fields (Device ID, Station ID, and User ID) can be used to enter information to identify the
BE1-11d. These fields are used by many of the reporting functions to identify the BE1-11d reporting the
information. Examples of BE1-11d identification field uses include station name, circuit number, relay
system, and purchase order.
Device Security
Security settings affect read and write access. Passwords provide access security for six distinct
functional access areas: Read, Control, Operator, Settings, Design, and Administrator. Each
username/password is assigned an access area with access to that area and each area below it. An
administrator password provides access to all six of the functional areas.
A second dimension of security is provided by the ability to restrict access for any of the access areas to
only specific communication ports. For example, you could set up security to deny access to control
commands through the Ethernet port.
Setting Groups
Four setting groups allow adaptive relaying to be implemented to optimize BE1-11d settings for various
operating conditions. Automatic and external logic can be employed to select the active setting group.
Clock
The clock is used by the logging functions to timestamp events. BE1-11d timekeeping can be self
managed by the internal clock or coordinated with an external source through a network or IRIG device.
A backup capacitor and additional battery backup are provided for the clock. During a loss of operating
power, the backup capacitor maintains timekeeping for up to 24 hours depending on conditions. As the
capacitor nears depletion, the backup battery takes over and maintains timekeeping. The backup battery
has a life expectancy of greater than five years depending on conditions.
IRIG
A standard unmodulated IRIG-B input receives time synchronization signals from a master clock.
Automatic daylight saving time compensation can be enabled and set for floating or fixed dates.
NTP (Network Time Protocol)
NTP synchronizes the real-time clock to network time servers through the Ethernet port. BESTCOMSPlus
is used to establish the priority of time reference sources available to the BE1-11d, IRIG-B, NTP, DNP,
and RTC (real-time clock). The NTP address is set using BESTCOMSPlus.
Communications
Three independent communication ports provide access to all BE1-11d functions. A USB (universal serial
bus) port is located on the front panel, a two-wire RS-485 port is located on the rear panel, and an
optional Ethernet port is located on the rear panel. The RS-485 and Ethernet ports are electrically
isolated.
Modbus® and DNP3 protocols are optionally available for the RS-485 or Ethernet communication port.
The IEC 61850 protocol is optionally available for the Ethernet port when RS-485 option is N (None).
Separate instruction manuals cover each available protocol. Consult the product bulletin or Basler Electric
for availability of these options and instruction manuals. Modbus sessions can be operated
simultaneously over the Ethernet and RS-485 ports.
System Parameters
All sensing is performed using an IT-D isolation module. Each IT-D isolation module includes two
channels that are capable of sensing either dc current or dc voltage. The dc system current is sensed
using an appropriately scaled 25. 50. 75. or 100-millivolt nominal metering shunt. DC voltages are sensed
by direct connection for nominal levels up to 1.500 Vdc. The BE1-11d can utilize two IT-D modules to
sense a single dc current and up to three dc voltages.
The IT-D digitally samples the sensed inputs at a rate proportional to the rectification system nominal
power input frequency. The sampling rate is established to maintain a high accuracy of the measurement
for a dc signal with ripple content.
High-speed fiber optic communications between the IT-Ds and the BE1-11d transmit the magnitudes of
the system measurement to the protection system.
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2026 Cld , All Rights Reserved K-JIANG All rights reserved