Introduction
The BE1-11d DC Power Protection System provides flexible, reliable, and
economical dc power protection, control, monitoring, and measurement
functions. The capabilities of the BE1-11d make it well suited to provide
comprehensive dc power protection. The BE1-11d offers dc overcurrent,
over/undervoltage, rate of rise, power, and thermal overload protection
functions as well as breaker reclosing and RTD (Resistance Temperature
Detector) inputs with remote module. It offers breaker and trip-circuit
monitoring, and oscillography and sequential events recording.
Control features include virtual selector switches, circuit breaker control,
virtual lockout, and variable-mode timers. System metering and status
information are available at the BE1-11d front panel and through the
BE1-11d communication ports. The system is suitable for mounting in
OEM cubicle or retrofit switchgear applications.

A front-panel USB port or optional rear Ethernet port enables local
communication between the BE1-11d and a PC operating with
BESTCOMSPlus® software. BESTCOMSPlus software simplifies the
commissioning process by providing a graphical interface for setting
the BE1-11d and configuring a protection and control scheme for your
application. Through BESTCOMSPlus, all BE1-11d settings and logic can
be retained in a file for printing or uploading to other BE1-11d protection
systems. Oscillography and sequential events records can be retrieved
from a BE1-11d, viewed, and printed.
Front-panel features include a large, backlit alphanumeric display and LED
indicators that display system parameters, BE1-11d settings, and BE1-11d
status. Pushbuttons enable navigation through the display menu, changes
to settings, resetting of targets (with password access), and direct access
to virtual switches.
Applications
The capabilities of the BE1-11d make it ideally suited for applications with
the following attributes:
• Isolation between the IT-D and the BE1-11d via fiber optic communications
• The flexibility provided by wide setting ranges, multiple setting groups, and
multiple coordination curves in one unit
• The economy provided by a multifunction unit. This one unit can provide all
of the protection, control, metering, and local and remote indication functions
required for typical applications.
• The small size and limited behind-panel projection facilitates modernizing
protection and control systems in existing equipment
• Coordinated protection with other BE1-11 protection systems on both ac and
dc sides of a rectifier
• High-speed Ethernet communications and protocol support
• The capabilities of a numeric multifunction relay
• IEC 61850 functionality
Features
The BE1-11d protection system includes many features for the protection,
monitoring, and control of dc switchgear. These features include protection
and control functions, metering functions, and reporting and alarm functions.
A highly flexible programmable logic system called BESTlogic™Plus allows
the user to apply the available functions with complete flexibility and
customize the system to meet the requirements of the protected dc switchgear.
Programmable I/O, extensive communication features, and an advanced user
interface provide easy access to the features provided.
The following information summarizes the capabilities of this multifunction
device. Each feature, along with its setup and use, is described in detail in
the later chapters of this manual.
General Features
HMI (Human-Machine Interface)
Each BE1-11d has a front-panel display and 12 LED indicators: Power
Supply Status, Relay Trouble Alarm, Minor Alarm, Major Alarm, Trip, and
Indicator 1 through 7 (programmable in BESTlogicPlus). The backlit, liquid
crystal display (LCD) allows the BE1-11d to replace local indication and
control functions such as panel metering, alarm annunciation, and control
switches. Four scrolling pushbuttons enable navigation through the LCD
menu tree. Parameters are changed using the Edit pushbutton. Targets,
alarms, and other registers are cleared with the Reset pushbutton.
In Edit mode, the scrolling pushbuttons provide data entry selections.
Edit mode is indicated by an LED on the Edit pushbutton.
Select Control Switch and Operate Control Switch pushbuttons provide a
means to control the logic switches.
The LCD has automatic priority logic to govern which metering values are
displayed on the screen so that when an operator approaches, the metering
data of most interest is automatically displayed without having to navigate
the menu structure. Scrollable metering parameters are selected on the
General Settings, Front Panel HMI settings screen in BESTCOMSPlus.
Device Information
The version of the embedded software (firmware), serial number, and style
number are available from the front panel or the communication ports.
Three free-form fields (Device ID, Station ID, and User ID) can be used
to enter information to identify the BE1-11d. These fields are used by
many of the reporting functions to identify the BE1-11d reporting the
information. Examples of BE1-11d identification field uses include station
name, circuit number, relay system, and purchase order.
Device Security
Security settings affect read and write access. Passwords provide access
security for six distinct functional access areas: Read, Control, Operator,
Settings, Design, and Administrator. Each username/password is assigned
an access area with access to that area and each area below it. An
administrator password provides access to all six of the functional areas.
A second dimension of security is provided by the ability to restrict access
for any of the access areas to only specific communication ports.
For example, you could set up security to deny access to control commands
through the Ethernet port.
Setting Groups
Four setting groups allow adaptive relaying to be implemented to optimize
BE1-11d settings for various operating conditions. Automatic and external
logic can be employed to select the active setting group.
Clock
The clock is used by the logging functions to timestamp events. BE1-11d
timekeeping can be self managed by the internal clock or coordinated with
an external source through a network or IRIG device.
A backup capacitor and additional battery backup are provided for the clock.
During a loss of operating power, the backup capacitor maintains timekeeping
for up to 24 hours depending on conditions. As the capacitor nears depletion,
the backup battery takes over and maintains timekeeping. The backup battery
has a life expectancy of greater than five years depending on conditions.
IRIG
A standard unmodulated IRIG-B input receives time synchronization signals
from a master clock. Automatic daylight saving time compensation can be
enabled and set for floating or fixed dates.
NTP (Network Time Protocol)
NTP synchronizes the real-time clock to network time servers through the
Ethernet port. BESTCOMSPlus is used to establish the priority of time
reference sources available to the BE1-11d, IRIG-B, NTP, DNP, and RTC
(real-time clock). The NTP address is set using BESTCOMSPlus.
Communications
Three independent communication ports provide access to all BE1-11d
functions. A USB (universal serial bus) port is located on the front panel,
a two-wire RS-485 port is located on the rear panel, and an optional
Ethernet port is located on the rear panel. The RS-485 and Ethernet ports
are electrically isolated.
Modbus® and DNP3 protocols are optionally available for the RS-485 or
Ethernet communication port.
The IEC 61850 protocol is optionally available for the Ethernet port when
RS-485 option is N (None). Separate instruction manuals cover each
available protocol. Consult the product bulletin or Basler Electric for
availability of these options and instruction manuals. Modbus sessions
can be operated simultaneously over the Ethernet and RS-485 ports.
System Parameters
All sensing is performed using an IT-D isolation module. Each IT-D isolation
module includes two channels that are capable of sensing either dc current
or dc voltage. The dc system current is sensed using an appropriately scaled
25. 50. 75. or 100-millivolt nominal metering shunt. DC voltages are sensed
by direct connection for nominal levels up to 1.500 Vdc. The BE1-11d can
utilize two IT-D modules to sense a single dc current and up to three dc
voltages.
The IT-D digitally samples the sensed inputs at a rate proportional to the
rectification system nominal power input frequency. The sampling rate is
established to maintain a high accuracy of the measurement for a dc signal
with ripple content.
High-speed fiber optic communications between the IT-Ds and the BE1-11d
transmit the magnitudes of the system measurement to the protection system.
wechat/whatsapp: