ABB SPAM150C Motor Protection Relay

From:ABB | author:Mr.Chen | Time :2024-08-13 | 975 view: | 🔊 Click to read aloud ❚❚ | Share:

Brief Introduction

The SPAM150C Motor Protection Relay is a general purpose combination relay designed primarily for the protection of AC motors for a variety of applications.

It combines a large number of protection functions in one unit. The relay provides a complete set of protection against motor damage caused by various electrical faults.

The relay is also suitable for other equipment requiring thermal overload protection, such as cable or power transformer feeders.

Summary of Protection Functions

The relay thermal overload unit protects the motor against short- and long-term overloads. The maximum permissible continuous load depends on the setting value 1.

Normally this setting value is taken as the rated full load current (FLC) of the motor at an ambient temperature of 40°C. The motor can be overloaded for a short period of time if the motor is not loaded.

When the motor current increases to 1.05I under the above conditions, the thermal overload unit starts after a certain delay.

If the ambient temperature of the motor is below 40°C for a long period of time, the setting value I. can be set to .05...1.10 times the full load current (FLC) of the motor. 1.10 times.

The short-time overload phenomenon mainly occurs during the starting process of the motor. The motor is normally allowed to start twice under cold conditions and once under hot conditions.

One start is permitted under hot conditions, therefore, depending on the starting time of the motor, an integrating value t determining the characteristics of the thermal overload unit can be derived.

This value can be easily determined from the time/current graph in the hot state. t curve is selected from the starting current versus the corresponding starting time (with an appropriate margin).

The t-curve is selected from the starting current versus the corresponding starting time (with an appropriate margin). Using the same value of t, the total permissible starting time of the motor under cold conditions can be found from the cold curve.

As a rule of thumb, for two cold starts or one hot start, the t-value is set to 1.6...2.0 times the starting time of the motor. ...2.0 times.

The thermal overload pre-warning signal can warn the operator to reduce the load of the motor when thermal overload occurs, thus avoiding unnecessary thermal overload tripping.

This can avoid unnecessary thermal overload tripping. The setting value of the pre-warning signal can be individually set to a certain percentage of the thermal overload tripping value.

Therefore, by choosing the appropriate pre-warning signal setting value, the motor can be operated close to the thermal capacity limit value while avoiding tripping due to prolonged overload.

Every time the motor is started, the start-up monitoring unit monitors the thermal consumption of the motor, usually in accordance with the It formula.

Alternatively, a fixed time limit overcurrent can be used. The latter is mainly used for equipment with non-motor loads.

In either case, a speed switch signal such as that mounted on the motor shaft to distinguish between motor blocking and normal starting can be programmed into the relay to control the output trip command.

to control the output trip command. A high value overcurrent protection unit (current cut-off) for protection against short-circuits between motor windings and short-circuits between phases of feeder cables.

The current setting value can be set so that it is automatically doubled during start-up. Therefore, the setting value can be set lower than the motor starting current.

Normally it can be set as low as 0.75 times the motor starting current. In addition, an appropriate action time should be set to match.

In this way, when the motor is blocked during operation, the current interruption protection unit can ensure reliable operation.

When the motor is controlled by a contactor, the high value overcurrent protection unit should be blocked and the fuse should be used to protect against short circuits.

The non-directional earth fault unit detects earth faults in the motor and feeder circuits. In the neutral point directly grounded or through the low impedance grounding system, the CT can be connected to a residual ground fault.

  • GE Multilin 750-P5-G5-S5-HI-A20-G 750 Management Relay
  • GE Multilin 750-P5-G5-D5-HI-A20-R 750/760 Feeder Mgmt Relay Series
  • GE Multilin 750-P5-G5-D5-HI-A20-G Management Relay
  • GE Multilin 750-P5-G1-D5-HI-A20-R Multilin 1A Zero Sequence Current Inputs
  • GE Multilin 750-P1-G1-S1-HI-A20-R-T-H Feeder Management Relays
  • GE Multilin 750-P1-G1-S1-HI-A20-R Feeder Management Relays
  • GE Multilin 750-P1-G1-D1-HI-A20-R Base Unit 750 Relay
  • GE Multilin 239-RTD-AN-H motor protection relay
  • GE Multilin 489-P5-HI-A20-T-H Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-T Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-E-H Relay Motor Management
  • GE Multilin 489-P1-LO-A20 489 Motor Management Relay Base Unit
  • GE Multilin SR469-P5-LO-A20-T Motor Management Relay
  • GE Relay from GE Grid Solutions SR469-P5-LO-A20-E
  • GE Multilin SR469-P5-LO-A20 Motor Management Relay with Case
  • GE Multilin SR469-P5-HI-A20-T 469 Series Relay
  • GE Multilin SR469-P1-HI-A1-E-H 469 Series Relay
  • GE Multilin SR469-P1-H1-A1-E 469 Series Relay
  • GE Multilin 469-P5-LO-A20-T Phase Current Input 5 A Phase CT Secondaries
  • GE Multilin 469-P5-LO-A20-E LO Control Power with 4-20mA Analog Outputs
  • GE Multilin 469-P5-LO-A20 Motor Management Relay
  • GE Multilin 469-P5-HI-A20-E-H Motor Management Relay
  • GE Multilin 469-P5-HI-A20 469 Motor Management Relay
  • GE Multilin 469-P1-HI-A1-E-H 469 Base Unit Motor Management Relay
  • GE Multilin 469-P1-H1-A1-E 469 Motor Mgmt Relay
  • Beckhoff ED2504 | EtherCAT Terminal, 4-channel PWM output
  • Beckhoff EL2262 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2258 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff EL2252 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A, timestamp
  • Beckhoff EL2212 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2202-0100 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2202 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A, push-pull, tristate
  • Beckhoff EL2124 | EtherCAT Terminal, 4-channel digital output, 5 V DC, 20 mA
  • Beckhoff EL2088 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, ground switching
  • Beckhoff EL2084 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, ground switching
  • Beckhoff EL2068 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, with channel diagnostics
  • Beckhoff EL2044 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with extended diagnostics
  • Beckhoff EL2042 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 x 4 A/1 x 8 A
  • Beckhoff ED2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, push-in, with channel diagnostics
  • Beckhoff EL2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with diagnostics
  • Beckhoff ED2032 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, push-in, with channel diagnostics
  • Beckhoff EL2032 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, with diagnostics
  • Beckhoff EL2024-0010 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2024 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2022 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2014 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, with extended diagnostics
  • Beckhoff ELX2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 30 mA, Ex i
  • Beckhoff ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in
  • Beckhoff EL2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A
  • Beckhoff EL2004 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A
  • Beckhoff ELX2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 45 mA, Ex i
  • Beckhoff EL2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A
  • TMEIC TM21-TG Series 2-Pole Generator
  • TMEIC TM21-TG Series 4-Pole Generator for Turbine Drive
  • TMEIC Air-Cooled Type Synchronous Generators
  • TMEIC TMdrive-XL85 Medium Voltage AC Drives
  • TMEIC TMdrive-30 Medium Voltage AC Drives
  • TMEIC TMdrive-MVG2 Medium Voltage AC Drives
  • TMEIC TMdrive-70 Medium Voltage AC Drives
  • TMEIC TMdrive-50 Medium Voltage AC Drives
  • TMEIC TMdrive-MVe2 Medium Voltage AC Drives
  • TMEIC TMdrive-XL80 Medium Voltage AC Drives
  • TMEIC TMdrive-XL75 Medium Voltage AC Drives
  • TMEIC TMdrive-XL55 Medium Voltage AC Drives
  • TMEIC TMdrive-70e2 Medium Voltage AC Drives
  • TMEIC TMdrive-Guardian Medium Voltage AC Drives
  • TMEIC TMdrive®-10e2 DP DC Drives
  • TMEIC TMdrive-DCe2 DC Drives
  • TMEIC Dynamic VAR Compensation – Dyna-VAR™
  • TMEIC PV Inverters SOLAR WARE 2500
  • TMEIC PV Inverters SOLAR WARE 2700
  • TMEIC PV Inverters SOLAR WARE 3200
  • TMEIC Power Plant Controller
  • TMEIC High-voltage motors 21-L series
  • TMEIC MV Motor & Drive Solutions for Power Generation
  • TMEIC AC Motors Rolling Mills
  • TMEIC TMdrive®-70 Medium Voltage 3-Level IEGT System Drive
  • TMEIC TMdrive®-70e2 Medium Voltage 3-Level IEGT System Drive
  • TMEIC TMdrive-MVe2 Reactive Power Control
  • TMEIC TMdrive®-30 Medium Voltage 3-Level IGBT System Drive
  • TMEIC Unified Controller nv Series
  • DEIF MVR-F215 Product description
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF PPM 300 Protection & power management
  • DEIF RMC-142D Current relay
  • DEIF GPU-3 hydro Generator protection unit
  • DEIF MVR-200 series Medium Voltage Relay
  • DEIF RMC-131D Current relay
  • DEIF MDR-2 Multi-differential relay
  • DEIF AGC 150 ATS: Advanced Generator Transfer Switch for Seamless Power Management
  • DEIF DVC 350 Digital automatic voltage regulator (AVR)
  • DEIF Digital Voltage Controller DVC 550
  • DEIF TAS-331DG AC transducer for active or reactive power
  • DEIF RMV-112D Undervoltage and overvoltage relay
  • DEIF DPS-1 DC Power Supply
  • DEIF DM 400 hydro Integrated systems
  • DEIF DBC-1 Battery charger
  • DEIF CSQ-3 Multi-function synchroscope
  • DEIF CODESYS Features Software - AWC 500 development package
  • DEIF AMC 300 Advanced Programmable Controller
  • DEIF AGI 400 Advanced graphical interface
  • DEIF BRW-2 & BW Analogue illuminated bridge wing indicators
  • DEIF AWC 500 - G59/3 Integrated G59/3 protection turbine controller unit
  • DEIF AWC 500 Advanced Controller
  • DEIF ASK & ASR Measuring transformer
  • DEIF ASC-4 Battery Automatic Sustainable Controller
  • DEIF ASC plant management Automatic sustainable controller
  • DEIF AOP Additional operator panel
  • DEIF AMC 600 Programmable automation controller with EtherCAT based I/O
  • DEIF AL8-2 Alarm panel
  • DEIF AGC 150 Hybrid Advanced Genset Controller
  • DEIF AGC 150 PMS Lite Simple power management controller
  • DEIF AGC 150 Generator Advanced Genset Controller
  • DEIF AGC 150 Remote Display Remote access and control unit
  • DEIF MVR-250 series Medium Voltage Relay
  • DEIF MVR-210 series Medium Voltage Relay
  • DEIF The SGC series
  • DEIF iE 350 Marine Highly flexible and cybersecure intelligent energy controller
  • DEIF iE 250 Marine Versatile and cybersecure intelligent energy controller for maritime applications
  • DEIF iE 150 Marine Simple and effective power management
  • DEIF iE 650 PLC Extreme robust Programmable Automation controller with EtherCAT based I/O
  • DEIF iE 350 PLC Robust right out of the box
  • DEIF iE 250 PLC Versatile and modular intelligent energy PLC controller
  • DEIF XL / BW / BRW-2 Illuminated indicators
  • DEIF SGC 120/121 Single Genset Controllers
  • DEIF Load Sharing Unit LSU-112DG
  • DEIF Automatic Genset Controller AGC-4