Relion® reliability, safety and dependability

The REF615 is a specialised feeder relay, perfectly matched for the protection, control, measurement and monitoring of utility substations and industrial power systems.

The REF615 is a member of the ABB Relion® family and part of its 615 protection and control product range.The 615 series of ANSIs is characterised by compactness and design flexibility.The 615 series has been designed from the ground up to unlock the full potential of the IEC 61850 standard for communication and interoperability of substation automation equipment.

Scope

Feeder protection for overhead lines, cable feeders and busbar systems in distribution substations

Key Benefits

Maximises capital by keeping assets working longer in designs that require less equipment and space

Reduce hazards and increase safety through safety-conscious design

Increase reliability by maintaining critical operations with consistent, high-quality power every minute of every day

Lower operating costs through effective energy management and maintenance strategies

More flexible system upgrades without rewiring or replacing components

Easy integration with non-proprietary IEC 61850 communications

Key Features

Pull-out design

Fault detection (CFD) for underground and overhead cables

High impedance (HIZ) fault detection

Arc Flash Detection (AFD)

Ring lug terminals for all inputs and outputs

Large, easy-to-read LCD

Description of the REF615

The REF615 is a dedicated feeder IED (Intelligent Electronic Device) designed to protect, control, measure and monitor utility substations and industrial power systems.

This includes radial, ring and grid distribution networks with or without distributed generation.

The REF615 is a member of the ABB Relion® product family and part of the 615 Protection and Control product family.

The 615 series of IEDs is characterised by its compact and withdrawable unit design.

The 615 series has been redesigned from the ground up to utilise the full potential of the IEC 61850 standard for communication and interoperability between substation automation devices.

Communication and interoperability between devices.

IEDs provide primary protection for overhead lines and cable feeders in distribution networks.

IEDs can also be used as backup protection in applications that require a separate redundant protection system.

Depending on the standard configuration selected, IEDs can be used to protect overhead lines and cable feeders in isolated neutral, resistance-grounded, compensating-grounded and solid-grounded networks.

The standard configuration IEDs are ready for use after application-specific setup.

The Series 615 IEDs support a range of communication protocols including IEC 61850 with GOOSE messaging, IEC 60870-5-103. Modbus® and DNP3. 2.

2. Standard Configurations The REF615 is available in nine standard configurations.

The standard signalling configurations can be changed via the graphical signalling matrix or via the graphical application functions of the Protection and Control IED Manager PCM600.

In addition, the application configuration function of the PCM600 supports the creation of multi-layer logic functions using various logic elements, including timers and triggers.

By combining protection functions with logic function blocks, the IED configuration can be adapted to the user's specific application requirements.

Protection Functions

IEDs provide directional and non-directional overcurrent and thermal overload protection, as well as directional and non-directional ground fault protection.

Some standard configurations are available with optional ground-fault protection based on conductivity, harmonics or power metering.

or wattage metering-based ground-fault protection. In addition, IEDs feature sensitive ground-fault protection, phase discontinuity protection,

instantaneous/intermittent earth fault protection, overvoltage and undervoltage protection, residual overvoltage protection, positive sequence undervoltage and negative sequence overvoltage protection.

IEDs with H and J configurations as standard also provide frequency protection, including overfrequency, 1MRS756379 M underfrequency, and rate-of-frequency-change protection.

With optional hardware and software enhancements, the IEDs also feature three light detection channels for arc fault protection of circuit breakers, busbars, and cable compartments in metal-enclosed indoor switchgear.

Arc-fault protection sensor interface The arc-fault protection sensor interface is available through an optional communications module.

Quick tripping increases worker safety and limits material damage in the event of an arc fault.

  • KEBA AR 281 ANALOGE INPUT BOARD
  • Engel Keba EC100 PLC Rack with PS244 CU211 PD242 AR181 TT081 DO321 DI325 (19821)
  • KEBA CU 313 Central Unit CU 313/C-SI/63036 Card 128MB
  • KEBA TM-240/A PLC MODULE
  • Keba D1633C E-Cpu-186B Cpu Control Circuit Board W/ D1630D
  • Keba Engel E-CON-CC100/A/22178 HMI Operator Control Display Panel
  • KEBA K2-200 CP 242/B controller module
  • KEBA KEVIEW V2 341/C-4400 HMI TOUCHSCREEN UNIT 84494 24 VDC
  • KEBA E-8-THERMO 1770B-1 Thermocouple circuit board
  • KEBA 3HAC12929-1 TEACH PENDANT
  • Keba KETOP C50 R/73810/06 KEBA PANEL OPERATOR DISPLAY
  • KEBA Kemro K2-400 DO 470/B 059707 Module
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Beckhoff EL2502-0010 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2502 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 0.5 A
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protectio
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • SAACKE FSC-01V3.02/V3.00 Industrial Combustion Controller
  • GE Multilin 750-P5-G5-S5-HI-A20-G 750 Management Relay
  • GE Multilin 750-P5-G5-D5-HI-A20-R 750/760 Feeder Mgmt Relay Series
  • GE Multilin 750-P5-G5-D5-HI-A20-G Management Relay
  • GE Multilin 750-P5-G1-D5-HI-A20-R Multilin 1A Zero Sequence Current Inputs
  • GE Multilin 750-P1-G1-S1-HI-A20-R-T-H Feeder Management Relays
  • GE Multilin 750-P1-G1-S1-HI-A20-R Feeder Management Relays
  • GE Multilin 750-P1-G1-D1-HI-A20-R Base Unit 750 Relay
  • GE Multilin 239-RTD-AN-H motor protection relay
  • GE Multilin 489-P5-HI-A20-T-H Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-T Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-E-H Relay Motor Management
  • GE Multilin 489-P1-LO-A20 489 Motor Management Relay Base Unit
  • GE Multilin SR469-P5-LO-A20-T Motor Management Relay
  • GE Relay from GE Grid Solutions SR469-P5-LO-A20-E
  • GE Multilin SR469-P5-LO-A20 Motor Management Relay with Case
  • GE Multilin SR469-P5-HI-A20-T 469 Series Relay
  • GE Multilin SR469-P1-HI-A1-E-H 469 Series Relay
  • GE Multilin SR469-P1-H1-A1-E 469 Series Relay
  • GE Multilin 469-P5-LO-A20-T Phase Current Input 5 A Phase CT Secondaries
  • GE Multilin 469-P5-LO-A20-E LO Control Power with 4-20mA Analog Outputs
  • GE Multilin 469-P5-LO-A20 Motor Management Relay
  • GE Multilin 469-P5-HI-A20-E-H Motor Management Relay
  • GE Multilin 469-P5-HI-A20 469 Motor Management Relay
  • GE Multilin 469-P1-HI-A1-E-H 469 Base Unit Motor Management Relay
  • GE Multilin 469-P1-H1-A1-E 469 Motor Mgmt Relay
  • Beckhoff ED2504 | EtherCAT Terminal, 4-channel PWM output
  • Beckhoff EL2262 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2258 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff EL2252 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A, timestamp
  • Beckhoff EL2212 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2202-0100 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2202 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A, push-pull, tristate
  • Beckhoff EL2124 | EtherCAT Terminal, 4-channel digital output, 5 V DC, 20 mA
  • Beckhoff EL2088 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, ground switching
  • Beckhoff EL2084 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, ground switching
  • Beckhoff EL2068 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, with channel diagnostics
  • Beckhoff EL2044 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with extended diagnostics
  • Beckhoff EL2042 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 x 4 A/1 x 8 A
  • Beckhoff ED2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, push-in, with channel diagnostics
  • Beckhoff EL2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with diagnostics
  • Beckhoff ED2032 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, push-in, with channel diagnostics
  • Beckhoff EL2032 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, with diagnostics
  • Beckhoff EL2024-0010 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2024 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2022 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2014 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, with extended diagnostics
  • Beckhoff ELX2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 30 mA, Ex i
  • Beckhoff ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in
  • Beckhoff EL2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A
  • Beckhoff EL2004 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A
  • Beckhoff ELX2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 45 mA, Ex i
  • Beckhoff EL2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A
  • TMEIC TM21-TG Series 2-Pole Generator
  • TMEIC TM21-TG Series 4-Pole Generator for Turbine Drive
  • TMEIC Air-Cooled Type Synchronous Generators
  • TMEIC TMdrive-XL85 Medium Voltage AC Drives
  • TMEIC TMdrive-30 Medium Voltage AC Drives
  • TMEIC TMdrive-MVG2 Medium Voltage AC Drives
  • TMEIC TMdrive-70 Medium Voltage AC Drives
  • TMEIC TMdrive-50 Medium Voltage AC Drives
  • TMEIC TMdrive-MVe2 Medium Voltage AC Drives
  • TMEIC TMdrive-XL80 Medium Voltage AC Drives
  • TMEIC TMdrive-XL75 Medium Voltage AC Drives
  • TMEIC TMdrive-XL55 Medium Voltage AC Drives
  • TMEIC TMdrive-70e2 Medium Voltage AC Drives
  • TMEIC TMdrive-Guardian Medium Voltage AC Drives
  • TMEIC TMdrive®-10e2 DP DC Drives
  • TMEIC TMdrive-DCe2 DC Drives
  • TMEIC Dynamic VAR Compensation – Dyna-VAR™
  • TMEIC PV Inverters SOLAR WARE 2500
  • TMEIC PV Inverters SOLAR WARE 2700
  • TMEIC PV Inverters SOLAR WARE 3200
  • TMEIC Power Plant Controller
  • TMEIC High-voltage motors 21-L series
  • TMEIC MV Motor & Drive Solutions for Power Generation
  • TMEIC AC Motors Rolling Mills
  • TMEIC TMdrive®-70 Medium Voltage 3-Level IEGT System Drive
  • TMEIC TMdrive®-70e2 Medium Voltage 3-Level IEGT System Drive
  • TMEIC TMdrive-MVe2 Reactive Power Control
  • TMEIC TMdrive®-30 Medium Voltage 3-Level IGBT System Drive
  • TMEIC Unified Controller nv Series
  • DEIF MVR-F215 Product description
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF PPM 300 Protection & power management
  • DEIF RMC-142D Current relay
  • DEIF GPU-3 hydro Generator protection unit
  • DEIF MVR-200 series Medium Voltage Relay