Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

ABB Emax 2 Harness double power automatic changeover system

From:ABB | author:Mr.Chen | Time :2024-11-27 | 957 view: | 🔊 Click to read aloud ❚❚ | Share:

Emax 2 Harness automatic double power conversion system

Intelligent and efficient

New third-generation technology - Emax 2 Harness dual power conversion system

- Embedded control system for more efficient power switching

- Intuitive user interface and user-friendly human-machine interaction

- Comprehensive safety features

The Emax 2 Harness dual power conversion system is designed for ‘two inlets and one busbar’ power supply lines.

Using ABB's latest third-generation circuit-breaker power conversion solution, the Emax 2 Harness eliminates the need for a traditional external stand-alone controller.

Emax 2 Harness can be directly through the intelligent off-trigger embedded logic to achieve efficient cooperation between the circuit breaker control, while supporting a variety of control modes, wiring, and so on.

The Emax 2 Harness supports multiple control modes, simple wiring, high reliability, shorter changeover times and intuitive control.

Emax 2 Harness is a high-performance automated power conversion system on the Emax 2 Ekip intelligent protective circuit breakers.

It provides safer and more reliable power switching without the need for additional control equipment, whilst providing circuit protection.

In industrial and power applications where efficiency and performance are delivered through digital communications, ABB is reinventing the way digital systems are embedded to help users achieve more efficient, safe and reliable power conversion.

ABB is reinventing the way digital systems are embedded to help customers realise more efficient, safe and stable power system solutions.

Efficient and simple control systems: smart circuit breakers with integrated embedded logic for shorter changeover times.

Simple connectivity: no need for a separate external controller for the circuit breaker, eliminating the need for complex wiring to external protection devices.

Higher Reliability: Ekip release provides a wide range of circuit breaker protection to ensure higher reliability. In the event of a fault, local and remote alarms can be realised, so that faults can be dealt with quickly.

The Emax 2 Harness automatic double power conversion system is equipped with power supply voltage and frequency detection functions.

In addition to the conventional conversion function, it also provides the closed-loop control function (parallel conversion) required by power plants and industries.

This ensures uninterrupted power supply for special applications and brings new solutions for power electronics, semiconductors, airports, petrochemicals, data centres and other industries.

Control Functions

The Emax 2 Harness dual power conversion system comes standard with the Touch intelligent tripper, which not only provides full mains circuit protection, but also supports multiple power sources.

switching functions:

- Automatic switchover - self-recovery - no self-recovery

- Manual changeover (not in parallel)

- Parallel switchover

The system can be fitted with control buttons and mode changeover switches mounted separately on the instrumentation door of the switchboard cabinet.

Manual/automatic/parallel switching is achieved by means of a mode switching button.

The system can be switched automatically according to a predefined procedure or switched to manual mode to exit automatic operation.

In the event of planned maintenance or power failure, manual parallel switching of the power supply is also possible to ensure that important loads are not interrupted by the switching process, thus ensuring continuity of the power supply.

Measurement functions

The Emax 2 Ekip Touch is equipped with a measurement module, which automatically collects and measures the status and parameters of the power supply and displays them visually on the circuit breaker's LCD screen.

Status indication

The Emax 2 Harness system can also be equipped with a status display function to show the operating status of the system to the user, which is convenient for on-site management.

Voltage Status Indication: The line voltage status of power supply 1/power supply 2 can be indicated by the LEDs. If the power supply voltage status is normal, the indicator light will be always on; if the voltage is abnormal (under/over-voltage), the indicator light will not be on.

Circuit breaker status indication: The status of power supply 1/power supply 2 (normal/abnormal) and the status of CB1/CB2/CB3 actuating circuit breakers (bright - closing; non-bright - opening) are visually displayed in the form of a single-line diagram of the system.

Synchronisation status indication: In parallel conversion mode, the synchronisation conditions (voltage/frequency/phase angle) of the two power sources of Power 1/Power 2 need to be met before parallel operation can be carried out.

Synchronisation indicator is on, it means that the two power sources are in synchronised state and parallel operation can be carried out; if the synchronisation indicator is not on, the two power sources are in unsynchronised state, then the circuit breaker will start safety blocking.

At this time, the executive circuit breaker starts safety blocking, and the switch can not execute the closing command in parallel operation mode to ensure the safety of the line.

Alarm Indication: The alarm indicator lights up when abnormal release occurs in the line.

Communication function: After installing communication module, the circuit breaker can have communication function, which can realise remote communication and intelligent control.

Other auxiliary functions

- RTC real-time time

- Key lock function

- Fault locking function

- Event record function

- Alarm function

  • Basler Electric 90-88800-102 Model PRS-250 Veri-Sync Relay
  • Basler Electric PRS-250 Veri-Sync Relay
  • Basler Electric BE1-50/51M-109 / BE15051M109 Overcurrent Relays
  • Basler Electric BE1-51-G1E-Z1S-B1C6F / BE151G1EZ1SB1C6F
  • Basler Electric STATIC VOLTAGE REGULATOR 840 VA SR4A SR4A1B10B3E
  • Basler Electric CBS 212 CURRENT BOOST SYSTEM 9265000100
  • Basler Electric CBS 212 CURRENT BOOST SYSTEM 9265000100
  • Basler Electric SR32A2B05B3E Static Voltage Regulator 40198
  • Basler Electric MOC2207 Motor Operated Control Potentiometer 90 72300420
  • Basler Electric SR4A1B05A3E Static Voltage Regulator
  • Basler Electric Underfrequency Power Relay Module T3EE1JA8NOF BEI-81
  • Basler Electric CBS 212A Current Boost System
  • Basler Electric PRS250 VERI SYNC RELAY 9088800102
  • Basler Electric PRS250 Veri-Sync Relay
  • Basler Electric SSR 63-12 Static Voltage Regulator 63VDC 100-139 VAC
  • Basler Electric - 51BRBNEAH001 - DGC-2020 Digital Genset Controller
  • Basler Electric BE1-81O/U T3ED1JB7N0F Digital Frequency Relay
  • Basler Electric BE1-32-A1E-E1C-B0N0F / BE132A1EE1CB0N0F Directional Power Relay
  • Basler Electric BE1-51-H5EZ2PB1N0F / BE151H5EZ2PB1N0F Time Overcurrent Relay
  • Basler Electric Relay BE1-50/51B-207 Overcurrent Relay
  • Basler Electric 9073800-103 Power Supply 110/120v-ac 12.8a Amp 15v-dc
  • Beckhoff EL2872-0010 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff EL2872 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff EL2869 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff ED2838 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff EL2838 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2819 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff ED2807 | EtherCAT Terminal, 32-channel digital output, 24 V DC, 0.5 A, push-in
  • Beckhoff EL2407 | EtherCAT Terminal, 32-channel digital output, 24 V DC, 0.5 A
  • Beckhoff EL2409 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff ED2809 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff EL2809 | EtherCAT Terminal, 16-channel digital output, 24 V DC, 0.5 A
  • Beckhoff EL2808 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff EL2798 | EtherCAT Terminal, 8-channel solid state relay output
  • Beckhoff EL2794 | EtherCAT Terminal, 4-channel solid state relay output
  • Beckhoff EL2788 | EtherCAT Terminal, 8-channel solid state relay output
  • Beckhoff EL2788 | EtherCAT Terminal, 8-channel solid state relay output
  • Beckhoff EL2788 | EtherCAT Terminal, 8-channel solid state relay output
  • Beckhoff EL2784 | EtherCAT Terminal, 4-channel solid state relay output
  • Beckhoff EL2722 | EtherCAT Terminal, 2-channel triac output
  • Beckhoff EL2712 | EtherCAT Terminal, 2-channel triac output
  • Beckhoff ELX2792 | EtherCAT Terminal, 2-channel solid state relay output
  • Beckhoff EL2652 | EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2642 | EtherCAT Terminal, 2-channel reed output
  • Beckhoff EL2634 | EtherCAT Terminal, 4-channel relay output
  • Beckhoff EL2624 | EtherCAT Terminal, 4-channel relay output
  • Basler Electric BE1-51 G1EZ1PA1N0FY Time Overcurrent Relay
  • Basler Electric Under-Voltage Relay BE1-27 A3EA1JN1N4F
  • Basler Electric BE1-27/59 Under/Over Voltage Relay A3F C4Y A0N2F
  • Basler Electric BE1-27/59A3FC4JB4B0F Voltage Relay
  • Basler BE1-27 A3EA1JA0S5F Under Voltage Relay
  • Basler Electric BE1-27 A3E C3J A1N6F Solid State Protective Relay
  • Basler Electric BE1-27/59 A3F E1L NON1F OVERVOLTAGE RELAY T245577
  • Basler Electric BE1-27A2EE1JA0A2F Voltage Relay
  • Basler Electric BE1-27 A3EE1JA1N6F Voltage Relay
  • Basler Electric L304KC / L304KC Camera Interface
  • Basler Electric BE3-25AX / BE325AX Synchronizing Check Relays
  • Basler Electric BE3-25-1D1N4 9319100106 480V Synchronizing Check Relays
  • Basler Electric BE3-25-1A1N4 SYNCH CHECK RELAY 9319100100
  • Basler Electric BE3-25-1C1N4 Synchronizing Check Relays
  • Basler Electric BE3-25-1S1N4 / BE3251S1N4 Synchronizing Check Relays
  • Basler Electric BE1-59N-A8E-E1L-N0S1F / BE159NA8EE1LN0S1F
  • NIB Basler Electric BE1-59N Style A5EE1KC0N0F Rev X Ground Fault Relay
  • Basler Electric BE1-59N A6E E1C B0N1F / BE159NA6EE1CB0N1F
  • Basler Electric BE1-59N GROUND FAULT RELAY T214750
  • Basler Electric BE1-59N-A5E-E1L-N0S1F / BE159NA5EE1LN0S1F
  • Basler Electric BE1-59N-A7E-D1J-D0N0F / BE159NA7ED1JD0N0F
  • Basler Electric BE1-59N A6EE1JC0N1F Ground Fault Overvoltage Relay
  • Basler Electric BE1-851 Overcurrent Relay Mechanism G5B2S0N
  • Basler Electric BE1-851 Overcurrent Relay H5A2S1N
  • Basler Electric DECS 125-15-B2C5 DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric PLA2400-12GM / PLA240012GM
  • Basler Electric BE1-50/51B-235 / BE15051B235 Self-Powered Time Overcurrent Relay
  • Basler Electric BE1-25 M9FA6PN4N0F / BE125M9FA6PN4N0F
  • Basler Electric BE1-27/59 UNDERVOLTAGE T238468
  • Basler Electric BE1-32R POWER RELAY, STYLE: D1EE1PA0N0F
  • Basler Electric BE1-32R ~ BE1-E1P-BON0F Protective Relay
  • Basler Electric BE1-32R POWER RELAY ONAN 0307-2661-09 B2EE1PA0N1F
  • Basler Electric Solid State Protective Relay BE1-32R E1EA1OA0N0F
  • Basler Electric Solid State Protective Relay BE1-32R Style B2ED1PB0N0F
  • Basler Electric Solid State Protective Relay BE1-32R STYLE C3ED1TA0S1F
  • Basler Electric C2EE1PA0N1F BE1-32R NSMP
  • Basler Electric BE1-32R PROTECTIVE RELAY STYLE A1E E1P BOS1P BE132R
  • Basler Electric BE1-32R Power Relay B3E E1R A0N1F
  • Basler Electric BE1-32R Power Solid State Relay, Style E2E A10 A0N0F
  • Basler Electric BE1-32R Power Relay A2E D1R A0N0F
  • Basler Electric Power Relay BE1-32R Style #: D3E E1R A0N1F
  • Basler Electric Power Relay BE1-32R D1E A1P A0N1F
  • Basler Electric BE1-32R Power Relay B2EE1PA0N1F Rev. AD
  • Basler Electric BE1-32R Power Solid State Relay F1F E1K A4N1F
  • Basler Electric BE1-700 Digital Protective Relay
  • Basler Electric BE1-700 E0N2X1N Digital Protective Relay
  • Basler Electric GROUND FAULT OVERVOLTAGE RELAY BE1-59N
  • Basler Electric BE1-851 / 887DB / 9289900180 DIFFERENTIAL RELAY
  • Basler Electric BE10493002 NSMP
  • Basler Electric SR4A2B01B3A / SR4A2B01B3A Static Voltage Regulator
  • Basler Electric BE1-51AK2EW7MB1NOF / BE151AK2EW7MB1NOF
  • Basler Electric EL 200-7 / EL2007 MINIMUM/MAXIMUM EXCITATION LIMITER
  • Basler Electric BE1-25 M9FA6PN4N0F / BE125M9FA6PN4N0F Sync-Check Relay
  • Alfa Laval M3 Gasketed plate heat exchanger
  • Alfa Laval TS35 Gasketed plate heat exchanger
  • Alfa Laval TL35 Gasketed plate heat exchanger
  • Alfa Laval TS20 Gasketed plate heat exchanger
  • Alfa Laval T2 Gasketed plate heat exchanger
  • Alfa Laval T15 Gasketed plate heat exchanger
  • Alfa Laval TL15 Gasketed plate heat exchanger
  • Alfa Laval TS6 Gasketed plate heat exchanger
  • Alfa Laval TL10 Gasketed plate heat exchanger
  • Alfa Laval T45 Gasketed plate heat exchanger
  • Alfa Laval TS50 Gasketed plate heat exchanger
  • Alfa Laval TL6 Gasketed plate heat exchanger
  • Alfa Laval T35 Gasketed plate heat exchanger
  • Alfa Laval T5 Gasketed plate heat exchanger
  • Alfa Laval T50 Gasketed plate heat exchanger
  • Alfa Laval TL3 Gasketed plate heat exchanger
  • Alfa Laval T25 Gasketed plate heat exchanger
  • Alfa Laval T10 Gasketed plate heat exchanger
  • Alfa Laval T6 Gasketed plate heat exchanger
  • Beckwith Electric M-2324C Adapter Panel
  • Beckwith Electric M-2278 Adapter Panel
  • Beckwith Electric M-2326 Adapter Panel
  • Beckwith Electric M-2356B Adapter Panel
  • Beckwith Electric M-2355B Adapter Panel
  • Beckwith Electric M-2347 Adapter Panel
  • Beckwith Electric M-2264B Adapter Panel
  • Beckwith Electric M-2148 Adpapter Panel