MONITOR FUNCTIONS

SYSTEM POWER-UP INHIBIT

The System Monitor provides a Power-up Inhibit function. This function allows each monitor to

inhibit its alarms during power-up or whenever a system supply voltage falls below its operating

level. After power-up, the inhibit function remains active for approximately 2 seconds.

RACK INHIBIT

When activated by a external contact closure this function places all monitors in bypass, disables

all alarms, zero scales all outputs, and de-energizes the system OK relay. The connections for this

function are located on the power input module (PIM) at the rear of the rack.

SUPPLY VOLTAGES OK

Seven LEDs located behind the front panel of the System Monitor are ON to indicate the voltage

supplies are functioning. The voltage supplies are +VRH, +VRL, +7.5V, +5V, REF, -7.5V, and -VT.

There is a green LED (SUPPLIES OK) on the front panel of the System Monitor. When this LED is on

all of the voltage supplies are functional.

SYSTEM RESET

The System Monitor provides the ability to cause a System Reset. Closing external contacts

through terminals on the PIM or pressing the RESET switch on the front panel will cause a System

Reset.

TRIP MULTIPLY

The most common use of this function is to prevent unwanted monitor alarms during certain

conditions of machine operation. In the operation of some machinery, it is impossible to avoid

some periods of "higher than normal" vibration. Examples include startup and coastdown,

especially if the operating speed is above rotor system balance resonances ("critical speeds"),

structural and other resonances, and changes in machine load or other operating conditions.

The Trip Multiply function causes the monitor alarm setpoints (both Alert and Danger) to increase

by a fixed amount, either two times (2X) or three times (3X), according to the ordering option. Only

those monitors ordered with this option will be affected. The Trip Multiply function is performed in

the System Monitor, but is an ordering option for each monitor. It must be specified at the time of

order placement and be installed at the factory.

Trip Multiply is activated by contact closure on the PIM. A red LED on the System Monitor front

panel indicates that the Trip Multiply function is active.

OK RELAY

The purpose of this relay is to provide a means to annunciate a problem that is detected with any

transducer system connected to the rack. The OK Relay is connected to the OK Circuit of every 

monitor in the rack. The OK Circuit continuously checks the condition of the transducer(s)

associated with that monitor. If the circuit detects a transducer problem, the OK LED on the front

of the affected monitor goes off and a relay drive signal is sent to the OK Relay in the System Monitor.

The OK Relay is located on the System Monitor PIM, is normally energized, and is a single-pole,

double-throw (SPDT) relay. Since it is normally energized, the relay also can be used to

annunciate when mains power to the rack is lost or interrupted. Either a system power-up inhibit

signal from the System Monitor or a not OK signal from any monitor in the rack will cause the OK

Relay to change state.

ALARM SETPOINT ADJUST

The System Monitor has two switches on the front panel that adjust alarm setpoint levels on each

monitor. One switch is for upscale adjustments, and the other switch is for downscale

adjustments.

DATA INTERFACE

The System Monitor supports the following Bently Nevada data interfaces: Dynamic Data

Manager (DDM), Transient Data Manager® (TDM), Serial Data Interface (SDI), Dynamic Data

Interface (DDI) and Transient Data Interface (TDI). The SDI and DDI are options of the System

Monitor and reside within the System Monitor slot of the rack. DDM, TDM and TDI are external

data interfaces which gain access to the rack through the PIM. There is an external version of the

SDI and DDI which connects to the PIM. For more information about these products consult a

Bently Nevada sales representative.

Keyphasor® TRANSDUCERS

The System Monitor receives input from four Keyphasor® transducers through terminals on the

PIM. Two of the Keyphasor® transducers are available to the monitors within the rack. All four of

  • Beckhoff EL2622-0010 EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2622 | EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2612 | EtherCAT Terminal, 2-channel relay output, 125 V AC, 30 V DC, 0.5 A AC, 2 A DC
  • Beckhoff EL2602-0010 EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2602 | EtherCAT Terminal, 2-channel relay output, 230 V AC, 30 V DC, 5 A
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2574 | EtherCAT Terminal, 4-channel LED output, pixel LED
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output
  • Beckhoff EL2535-0100 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2535-0050 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output
  • KEBA KEVIEW V2 341/C-4400 HMI TOUCHSCREEN UNIT
  • KEBA KEMRO K2-200 BL250/A BL 250/A Bus Coupler Module
  • Keba E-CON-14 Operator Interface Panel
  • KEBA CP 255/W Plc Module
  • KEBA CU 212 ZENTRALBAUGRUPPE
  • KEBA CU211/0 25817 Ind 06
  • KEBA RS 091 POWER SUPPLY MODULE
  • KEBA E-SP-CCEC/22180 Panel
  • KEBA E-CPU-186B Control Circuit Board D1633C
  • Keba Kemro K2-200 Control CP 255/X, Part. 072076
  • KEBA analog module, AR281, AR 281
  • KEBA BL250/B Bus link module
  • KEBA Kemro K2-400, DO 470/A, Part No. 054945
  • KEBA HAITAN SA900 Operator Panel
  • KEBA DO 321 module DO 321/B
  • KEBA KeTop C20t-t00-Ar0-KMT Tech Pendant by Karl Mayer
  • KEBA HT401/BENNINGER/5M/55268 TEACH PENDANT HT401BENNINGER/5M/55268
  • KEBA AR 281 ANALOGE INPUT BOARD
  • Engel Keba EC100 PLC Rack with PS244 CU211 PD242 AR181 TT081 DO321 DI325 (19821)
  • KEBA CU 313 Central Unit CU 313/C-SI/63036 Card 128MB
  • KEBA TM-240/A PLC MODULE
  • Keba D1633C E-Cpu-186B Cpu Control Circuit Board W/ D1630D
  • Keba Engel E-CON-CC100/A/22178 HMI Operator Control Display Panel
  • KEBA K2-200 CP 242/B controller module
  • KEBA KEVIEW V2 341/C-4400 HMI TOUCHSCREEN UNIT 84494 24 VDC
  • KEBA E-8-THERMO 1770B-1 Thermocouple circuit board
  • KEBA 3HAC12929-1 TEACH PENDANT
  • Keba KETOP C50 R/73810/06 KEBA PANEL OPERATOR DISPLAY
  • KEBA Kemro K2-400 DO 470/B 059707 Module
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Beckhoff EL2502-0010 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2502 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 0.5 A
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protectio
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • SAACKE FSC-01V3.02/V3.00 Industrial Combustion Controller
  • GE Multilin 750-P5-G5-S5-HI-A20-G 750 Management Relay
  • GE Multilin 750-P5-G5-D5-HI-A20-R 750/760 Feeder Mgmt Relay Series
  • GE Multilin 750-P5-G5-D5-HI-A20-G Management Relay
  • GE Multilin 750-P5-G1-D5-HI-A20-R Multilin 1A Zero Sequence Current Inputs
  • GE Multilin 750-P1-G1-S1-HI-A20-R-T-H Feeder Management Relays
  • GE Multilin 750-P1-G1-S1-HI-A20-R Feeder Management Relays
  • GE Multilin 750-P1-G1-D1-HI-A20-R Base Unit 750 Relay
  • GE Multilin 239-RTD-AN-H motor protection relay
  • GE Multilin 489-P5-HI-A20-T-H Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-T Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-E-H Relay Motor Management
  • GE Multilin 489-P1-LO-A20 489 Motor Management Relay Base Unit
  • GE Multilin SR469-P5-LO-A20-T Motor Management Relay
  • GE Relay from GE Grid Solutions SR469-P5-LO-A20-E
  • GE Multilin SR469-P5-LO-A20 Motor Management Relay with Case
  • GE Multilin SR469-P5-HI-A20-T 469 Series Relay
  • GE Multilin SR469-P1-HI-A1-E-H 469 Series Relay
  • GE Multilin SR469-P1-H1-A1-E 469 Series Relay
  • GE Multilin 469-P5-LO-A20-T Phase Current Input 5 A Phase CT Secondaries
  • GE Multilin 469-P5-LO-A20-E LO Control Power with 4-20mA Analog Outputs
  • GE Multilin 469-P5-LO-A20 Motor Management Relay
  • GE Multilin 469-P5-HI-A20-E-H Motor Management Relay
  • GE Multilin 469-P5-HI-A20 469 Motor Management Relay
  • GE Multilin 469-P1-HI-A1-E-H 469 Base Unit Motor Management Relay
  • GE Multilin 469-P1-H1-A1-E 469 Motor Mgmt Relay
  • Beckhoff ED2504 | EtherCAT Terminal, 4-channel PWM output
  • Beckhoff EL2262 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2258 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff EL2252 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A, timestamp
  • Beckhoff EL2212 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2202-0100 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2202 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A, push-pull, tristate
  • Beckhoff EL2124 | EtherCAT Terminal, 4-channel digital output, 5 V DC, 20 mA
  • Beckhoff EL2088 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, ground switching
  • Beckhoff EL2084 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, ground switching
  • Beckhoff EL2068 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, with channel diagnostics
  • Beckhoff EL2044 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with extended diagnostics
  • Beckhoff EL2042 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 x 4 A/1 x 8 A
  • Beckhoff ED2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, push-in, with channel diagnostics
  • Beckhoff EL2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with diagnostics
  • Beckhoff ED2032 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, push-in, with channel diagnostics
  • Beckhoff EL2032 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, with diagnostics
  • Beckhoff EL2024-0010 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2024 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2022 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2014 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, with extended diagnostics
  • Beckhoff ELX2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 30 mA, Ex i
  • Beckhoff ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in
  • Beckhoff EL2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A
  • Beckhoff EL2004 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A
  • Beckhoff ELX2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 45 mA, Ex i
  • Beckhoff EL2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A
  • TMEIC TM21-TG Series 2-Pole Generator
  • TMEIC TM21-TG Series 4-Pole Generator for Turbine Drive
  • TMEIC Air-Cooled Type Synchronous Generators